Installation
Continued
WARNING - RISK OF FIRE! Wiring to power source must not be pinched or against a sharp edge.
WARNING - RISK OF FIRE! To prevent a possible fire, do not block air intake or exhaust in any manner. Do not use on soft surfaces where openings may become blocked.
WARNING - RISK OF FIRE! Do not blow or place insulation against the firebox.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors in the vicinity of this or any other heater.
A junction box is provided to hard wire unit to either a 15 amp (120/60) or 20 amp (240/60), 120 Volt 60 Hz grounded circuit.
Tools and building supplies required for installation:
• | Saw | • Square | |
• | Pliers | • | Gloves |
• | Hammer | • | Level |
WARNING: Control panel door on this heater cannot, in any way, be covered as it may create a fire hazard.
IMPORTANT: If installing a perimeter trim kit, you must install shoulder screws before inserting fireplace into opening. See instructions included with trim kit. If installing a mantel, you must follow clearance instructions (see Installation Clearances, page 5).
Platform/Subflooring
36 1/2"
7 1/2"
41 1/4"
Figure 6 - Framing Dimensions
• | Phillips screwdriver | • | Surround |
• | Framing materials | • | Electric drill/bits |
•Tape measure
•
•Caulking material
CAUTION: Provide adequate clearances around the air openings and adequate accessibility clearances for servicing and proper operations.
423/8"
293/8"
These Dimensions
Allow for 11 5/8" of
Clearance to Side
Wall of Fireplace
and 10' Clearance
to Perpendicular
Side Walls
11 5/8"
58 1/4"
Figure 7 - Corner Dimensions
6 | www.desatech.com |