TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame goes

1. Control knob not fully pressed in

1.

Press in control knob fully

out when control knob is re-

2. Control knob not pressed in

2.

After ODS/pilot lights, keep con-

leased

 

long enough

 

trol knob pressed in 30 seconds

 

3.

Safety interlock system has

3.

Wait one minute for safety in-

 

 

been triggered

 

terlock system to reset. Repeat

 

4.

Equipment shutoff valve not

 

ignition operation

 

4.

Fully open equipment shutoff

 

 

fully open

 

valve

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

6.

Pilot flame not touching ther-

6.

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing

 

B) Clean ODS/pilot (see

 

 

pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 19) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

 

 

 

 

Burner does not light after ODS/

1. Burner orifice is clogged

1.

Clean burner (see Cleaning

pilot is lit

 

 

 

and Maintenance, page 19)

 

 

 

 

or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

 

 

 

Delayed ignition of burner

1. Manifold pressure is too low

1.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 19)

 

 

 

 

or replace burner orifice

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 19)

 

2.

Burner damaged

 

or replace burner orifice

 

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

114683-01B

www.desatech.com

21

Page 21
Image 21
Desa RG30NT ODS/pilot lights but flame goes, Press in control knob fully, Leased Long enough, Safety interlock system has