OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
|
|
|
|
|
Heater produces unwanted | 1. | Heater burning vapors from | 1. | Ventilate room. Stop using |
odors |
| paint, hair spray, glues, etc. |
| odor causing products while |
|
| (see IMPORTANT statement |
| heater is running |
|
| above) | 2. | Refill supply tank |
| 2. | Low fuel supply (propane/LP | ||
|
| gas only) | 3. | Locate and correct all leaks |
| 3. | Gas leak. See Warning |
| (see Checking Gas Connec- |
|
| statement above |
| tions, page 13) |
|
|
|
|
|
Heater shuts off in use (ODS | 1. | Not enough fresh air is | 1. | Open window and/or door for |
operates) |
| available |
| ventilation |
| 2. | Low line pressure | 2. | Contact local natural or pro- |
| 3. | ODS/pilot is partially |
| pane/LP gas company |
| 3. | Clean ODS/pilot (see Cleaning | ||
|
| clogged |
| and Maintenance, page 19) |
|
|
|
|
|
Gas odor even when control knob | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks |
is in OFF position |
| statement above |
| (see Checking Gas Connec- |
| 2. | Control valve defective |
| tions, page 13) |
| 2. | Replace control valve | ||
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between con- | 1. | Take apart gas tubing and |
|
| trol valve and burner |
| remove foreign matter |
| 2. | Gas leak. See Warning | 2. | Locate and correct all leaks |
|
| statement above |
| (see Checking Gas Connec- |
|
|
|
| tions, page 13) |
|
|
|
|
|
Moisture/condensation noticed | 1. | Not enough combustion/ven- | 1. | Refer to Air for Combustion |
on windows |
| tilation air |
| and Ventilation requirements |
|
|
|
| (page 5) |
www.desatech.com | 23 |