Desa RG30P, GG30NT, FG30PT, FG30NT, RG30NT, GG30PT Gas leak. See Warning, Statement above

Models: GG30PT BG30N FG30NT RG30N GG30NT FG30P GG30N GG30P FG30PT FG30N RG30NT BG30PT RG30P BG30NT BG30P

1 32
Download 32 pages 51.75 Kb
Page 23
Image 23

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Ventilate room. Stop using

odors

 

paint, hair spray, glues, etc.

 

odor causing products while

 

 

(see IMPORTANT statement

 

heater is running

 

 

above)

2.

Refill supply tank

 

2.

Low fuel supply (propane/LP

 

 

gas only)

3.

Locate and correct all leaks

 

3.

Gas leak. See Warning

 

(see Checking Gas Connec-

 

 

statement above

 

tions, page 13)

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is

1.

Open window and/or door for

operates)

 

available

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

3.

ODS/pilot is partially

 

pane/LP gas company

 

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 19)

 

 

 

 

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

2.

Control valve defective

 

tions, page 13)

 

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

trol valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 13)

 

 

 

 

 

Moisture/condensation noticed

1.

Not enough combustion/ven-

1.

Refer to Air for Combustion

on windows

 

tilation air

 

and Ventilation requirements

 

 

 

 

(page 5)

114683-01B

www.desatech.com

23

Page 23
Image 23
Desa RG30P, GG30NT, FG30PT, FG30NT, RG30NT, GG30PT, BG30NT, BG30PT Gas leak. See Warning, Statement above