Desa FLAME-MAX Vintage Installing Logs, Pressure Testing Heater Gas Connections, Installation

Models: FLAME-MAX Vintage FLAME-MAX Golden

1 48
Download 48 pages 22.76 Kb
Page 15
Image 15
Pressure Testing Heater Gas Connections

INSTALLATION

Checking Gas Connections (Cont.) Installing Logs

15

INSTALLATION

Continued

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 19).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (Thermostat-Controlled Models), to control valve (Manually-Controlled Models), or to gas control (Remote- Ready Models)(see Figures 20 and 21). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 18 through 23, de- pending on your model). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 19 for Thermostat-Controlled models, page 20 for Manually-Controlled Models, or page 22 for Remote-Ready Models).

Equipment

ShutoffOpen

Valve

Closed

Figure 19 - Equipment Shutoff Valve

Equipment

Thermostat Gas

Shutoff Valve

 

Valve or Control

 

Valve Location

Gas Meter

 

Figure 21 - Checking Gas Joints (Natural Gas Only)

INSTALLING LOGS

INSTALLING LOGS WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Equipment

 

Shutoff Valve

Thermostat Gas

Propane/LP

Valve or Control

Supply Tank

Valve Location

Figure 20 - Checking Gas Joints (propane/LP only)

Vintage Oak Two-Piece Log SetCAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.

Vintage Oak Two-Piece Log Set

It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front log on top of the grate and over front posts on chassis (see Figure 22, page 15).

2.Place rear log on rear of chassis (see Figure 22, page 15). Slide log forward so that it sits against rear posts on chassis. MPORTANT: Make sure logs do not cover any burner ports (see Figure 23, page 15).

3.Place lava rock around base of heater if desired.

For moreManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

110399-01A

Page 15
Image 15
Desa FLAME-MAX Vintage Installing Logs, Pressure Testing Heater Gas Connections, Vintage Oak Two-PieceLog Set, Continued