Desa FLAME-MAX Golden, FLAME-MAX Vintage Optional Positioning Of Thermostat Sensing Bulb

Models: FLAME-MAX Vintage FLAME-MAX Golden

1 48
Download 48 pages 22.76 Kb
Page 28
Image 28
OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

28

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB (THERMOSTAT-CONTROLLED MODELS ONLY)

For Masonry and Factory-Built Metal Fireplace

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

(Thermostat-Controlled Models Only)

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermostat sensing bulb else- where, an adhesive-backed mounting clip is available.

Tools needed: 1/4" hex driver or socket

Thermostat

Thermostat Capillary Sensing Bulb

Screw

Retaining

Clamp

Figure 44 - Adhesive-backed

Figure 45 - Removing

Mounting Clip

Thermostat Sensing Bulb

1.

Remove logs. Locate the gas valve assembly and thermostat

 

sensing bulb (see Figure 43).

2.

With 1/4" hex driver or socket, loosen the thermostat screw.

 

Carefully slide the thermostat sensing bulb out of the retaining

 

clamp (see Figure 45).

 

Note: Do not remove the screw. Make sure you tighten the

 

screw after removing the thermostat sensing bulb.

 

IMPORTANT: Do not force or bend the thermostat sensing

 

bulb or capillary.

3.

The thermostat sensing bulb may be located to the lower right

 

front side of fireplace. Determine location of sensing bulb, but

Thermostat Sensing Bulb

Adhesive- backed Mounting Clip

Thermostat Sensing Bulb

Adhesive- backed Mounting Clip

do not mount sensing bulb until step 5. If you have a masonry

fireplace, see Figure 46 for location. If you have a factory-

built metal fireplace, see Figure 47 for location. If your fire-

place has glass doors, position sensing bulb directly behind

door gap on right bottom side (see Figure 48).

Figure 46 - Locating Thermostat

Figure 47 - Locating Thermostat

Sensing Bulb on Masonry

Sensing Bulb on Factory-built

Fireplace

Metal Fireplace

4. The mounting clip must be a minimum of 3" from bottom of

fireplace to prevent crimping of capillary. Once you have de-

cided on a location, clean the area thoroughly. Remove the pa-

per backing from the adhesive on back of mounting clip. Press

the clip into the new location so that the thermostat sensing bulb

will be positioned vertically with the capillary at the bottom

(see Figure 49). Slide the thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Gas Valve

Assembly

Thermostat Sensing Bulb

Adhesive- backed Mounting Clip

Glass Doors

Thermostat Sensing Bulb

Adhesive- backed Mounting

Clip

Capillary

Do Not

(Thermostat-Controlled Models Only) Crimp Capillary

FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE Thermostat

MountingSensing Bulb

Bracket

Figure48-InstallingThermostat

Figure 49 - Positioning the

Sensing Bulb behind Glass

Thermostat Sensing Bulb in

Doors

the Vertical Position with the

 

Capillary at the Bottom

Figure 43 - Location of Gas Valve Assembly and Thermostat

Sensing Bulb

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

110399-01A

Page 28
Image 28
Desa FLAME-MAX Golden Optional Positioning Of Thermostat Sensing Bulb, For Masonry And Factory-Builtmetal Fireplace