Master Bilt TAF-48 ERC2, TAF-27 ERC2, TAF-74 ERC2 manual ALHi, 50 F

Models: TAF-74 ERC2 TAF-27 ERC2 TAF-48 ERC2

1 18
Download 18 pages 21.7 Kb
Page 12
Image 12
ALHi

High

ALHi

High temperature

°

°

setpoint that will

Range: from – 40 to 83 F or –40 to

50 F

Temperature

 

23°C

 

Alarm

 

make the alarm go

 

 

 

 

off and the error

 

 

 

 

message appear on

 

 

 

 

the display

 

 

Important Note: To change from degrees C to F or vice-versa, the user must reprogram all the parameters that are related to the temperature. The unit does not convert the parameters automatically from degrees F to C or vice-versa.

Example 1 - To adjust the time-of-day

-Press and hold SET for 5 seconds

-Press SET again

-Press UP or DOWN until the correct time appears on the display

-Press SET to accept the new time

-Press DOWN twice to exit the programming mode

Example 2 - To set one defrost a day, at 11:59 PM

-Press and hold SET and DOWN for 10 seconds

-Press DOWN five times to get to go to the Defrost Interval (dFIn)

-Press SET to change the parameter

-Press DOWN until tdAy appears on the display

-Press SET to accept the option

-Press DOWN seven times to go to the Number of Defrosts (noDF)

-Press SET to change it

-Press UP or DOWN until 1 appears on the display

-Press SET to accept the change

-Press DOWN to go to Defrost Start Time (dEF1)

-Press SET to change the time

-Press UP or DOWN until the 11:59 PM appears on the display

-Press SET

-Press DOWN ten times to exit the programming level

Error Codes

Display

Control Status

Er 1

ERC Fault – software or hardware failure

Er 2

ERC Communication Fault – indicates that there is a problem with the display module cable

Er 3

Zone Sensor Fault – indicates an open or shorted temperature sensor

Er 4

Evaporator Sensor Fault – indicates an open or shorted evaporator sensor

Er 5

ERC Fault – software or hardware failure

Er 6

Low Temperature Alarm – indicates that the temperature has dropped below the low alarm setpoint

Er 7

High Temperature Alarm – indicates that the temperature has gone above the high alarm setpoint

Er 8

Relay and display modules are incompatible

For Error Codes 1, 2 and 5 cut the power to the unit and correct the problem to reset the display.

For Codes 3 and 4, press the UP or DOWN button on the display to reset the error message. If the display still shows the message, the sensor must be replaced.

The Error Codes 6 and 7 will be automatically reset once the temperature is back within the two set points.