CONDENSATE PAN INSTALLATION FOR TOP MOUNT CABINETS ONLY

1.Before moving cabinet into place, remove the condensate pan from the top unit compartment.

2.Using the two screws supplied with the pan, attach the pan to the back of the cabinet at the two holes near the bottom of the plastic drain line. Be sure pan is NOT located directly under cabinet. When the pan is attached, feed drain line into the open hole in screen and clamp the heater conduit to the back of the cabinet. Due to this condensate pan, this case must be a minimum of 6” from the wall.

3.If cabinet must be located next to wall on legs, the pan can be located under the cabinet. When this is done, steam will accumulate on the bottom

of the cabinet if there is not adequate ventilation, and rusting of the bottom of the cabinet will occur.

4.

Low Temperature Freezers – TAF Models

The TAF - 27 models are cord connected and operate on a 15 amp, 115/60/1 circuit. The TAF – 48 and TAF- 74 models have two junction boxes mounted on top of the cabinet, at the right rear, for permanent connection to power. One junction box is labeled 115v. (black, white and green lead) ; the other is labeled 230v. (black, red and green lead). These boxes should be connected to their respective power source. Check inside the cabinet for the power requirement for each cabinet. The label is located in the upper left hand corner.

ERC 2 – ELECTRONIC REFRIGERATION CONTROL

Programming

To access the pushbuttons on the ERC2, flip up the front cover using the tabs on the side of the cover as shown.

The ERC 2 control initially powers up displaying 12:00 AM otherwise it will show the last configured selection (time or temperature). If a power outage occurs during normal operation, the control will maintain the correct time-of-day using a capacitor (batteries are not required). The time will be maintained for up to 100 hours when the capacitor is fully charged.