Master Bilt TAF-74 ERC2, TAF-48 ERC2, TAF-27 ERC2 manual ALrd, nodF, FAnd, ALLo, 2 min, 0 min, 50 F

Models: TAF-74 ERC2 TAF-27 ERC2 TAF-48 ERC2

1 18
Download 18 pages 21.7 Kb
Page 11
Image 11
ALrd

Minimum

Con

Minimum time that

 

Range: from 0 to 15 min

2 min.

Compressor

 

the compressor

 

 

 

On Time

 

remain turned on

 

 

 

Alarm Delay

ALrd

Time delay before

 

Range: from 0 to 59 min

30 – for LT

 

 

the alarm goes off

 

 

45 – for MT

 

 

after the

 

 

 

 

 

temperature fall

 

 

 

 

 

off the two alarm

 

 

 

 

 

set points

 

 

 

Compressor

CPrn

Time the

 

 

12 – for MT

Run Time

 

compressor runs

 

 

 

 

 

between defrosts

 

 

 

Number of

nodF

Number of defrosts

 

from 0 to 8 (0 means 1 defrost

N/A – for LT

Defrosts

 

per day

 

every 48 hours)

0 – for MT

Defrost Start

dEF1-8

Start time of each

 

 

N/A

Time

 

defrost

 

 

 

Defrost

dEFd

Defrost duration

 

Range: from 0 min to 4 hours

35 – for LT

Duration

 

time (back-up for

 

 

0 – for MT

 

 

defrost

 

 

 

 

 

termination

 

 

 

 

 

temperature)

 

 

 

Fan Delay

FAnd

Delay time for the

 

Range: from 0 to 15 min

2 – for LT

 

 

fan after defrost

 

 

0 – for MT

 

 

(back-up for fan

 

 

 

 

 

cut-in

 

 

 

 

 

temperature)

 

 

 

Pump Down

Pudn

Pump down duration

 

Range: from 0 to 59 min

0 min.

Drip Time

driP

Drip time duration

 

Range: from 0 to 59 min

2 – for LT

 

 

 

 

 

0 – for MT

Setpoint

°

Cut-in temperature

 

°

°

diF

differential

 

Range: from 1 to 25

10 F–for LT

Differential

 

 

 

7oF – for MT

 

 

Note: cut-in is cut-

 

 

 

 

 

out plus differential

 

 

 

Temperature

tdEF

Temperature that

 

Range: from – 40 to 40°F or – 40 to

N/A

Initiated

 

will initiate a

 

4°C

 

Defrost

 

defrost cycle

 

 

 

Defrost

dEF°

Temperature in the

 

Range: from 0 to 75°F or –18 to

50° F

Termination

 

evaporator that

 

25°C

 

Temperature

 

will terminate the

 

 

 

 

 

defrost cycle

 

 

 

Fan Cut-In

FAn°

Temperature in the

 

Range: from – 40 to 60°F or – 40 to

30° F–for LT

Temperature

 

evaporator that

 

23°C

60oF–for MT

 

 

will turn the fan

 

 

 

 

 

on after defrost

 

 

 

Low

ALLo

Low temperature

 

°

°

setpoint that will

 

Range: from – 40 to 83 F or – 40 to

-40F–for LT

Temperature

 

 

23°C

32oF–for MT

Alarm

 

make the alarm go

 

 

 

 

 

off and the error

 

 

 

 

 

message appear on

 

 

 

 

 

the display

 

 

 

 

 

11

 

 