Master Bilt TAF-27 ERC2, TAF-48 ERC2, TAF-74 ERC2 manual dSPL, 12Hr, Elec, Efan, Cfan, dFin, CoFF

Models: TAF-74 ERC2 TAF-27 ERC2 TAF-48 ERC2

1 18
Download 18 pages 21.7 Kb
Page 10
Image 10
dSPL

To change the other parameters (Second Level) follow these steps:

Step 1

 

Press and hold SET and DOWN for 10 seconds. The display

 

and

will show dSPL

 

 

 

 

 

Step 2

 

Press SET to change the parameter

 

 

 

Step 3

 

Press UP or DOWN to change the options, time or temperature

 

or

for the current parameter

 

 

 

 

 

Step 4

 

Press SET to accept the new value

 

 

 

Step 5

 

Press DOWN to go to the next parameter, then go back to Step

 

 

2. After the last parameter is displayed (ALHi), the display will

 

 

go back to the normal operating condition

Note: to scroll down the parameters without changing them, press the DOWN button.

List of Parameters

Here is a list of the parameters that can be changed in the Second Level of programming, as well as their options and ranges.

Note: Master-Bilt’s Set point Temperature (Set) is set at a recommended –10°F at the factory.

Parameter

Displa

Description

 

Range / Options

Master-

 

y

 

 

 

Bilt’s

 

Symbo

 

 

 

Factory

 

l

 

 

 

Setting

Display Status

dSPL

Information shown

 

tdAy time-of-day

 

 

 

on the display

 

rSP° – zone temperature

rSP

 

 

during operation

 

CyCL – cycle between time and

 

 

 

conditions

 

zone temperature

 

 

 

 

 

Epr° – evaporator coil temperature

 

Clock Format

CLHr

Time Format(12 or

 

12Hr – AM/PM format

12Hr

 

 

24 hours mode)

 

24Hr – 24 hour format

 

Temperature

°dSP

Temperature

 

°F – degrees Fahrenheit

°F

Format

 

degrees

 

°C – degrees Celsius

 

Defrost Type

dFtP

Type of defrost used

 

ELEC – electric defrost / off cycle

ELEC

 

 

in the application

 

HgAS – hot gas defrost

 

Fan Status

EFAN

Enable or not the

 

no – fan is turned off during defrost

No – for LT

During Defrost

 

fan during defrost

 

yES – fan remains on during defrost

yES–for MT

Fan Status

CFAN

Enable or not fan during

 

on – fan on during normal mode

on

During Normal

 

normal compressor

 

CyCP – fan cycles with compressor

 

Mode

 

on/off mode

 

 

 

Defrost

dFin

Type of defrost

 

TdAy time-of-day setpoint

ddEF–for LT

Interval

 

interval

 

CPrn – compressor run time

CPrn–for MT

 

 

 

 

tdEF – temperature initiated defrost

 

 

 

 

 

ddEF – demand initiated defrost

 

Minimum

CoFF

Minimum time that

 

Range: from 0 to 15 min

2 min.

Compressor

 

the compressor

 

 

 

Off Time

 

remain turned off

 

 

 

 

 

10

 

 

Page 10
Image 10
Master Bilt TAF-27 ERC2, TAF-48 ERC2, TAF-74 ERC2 manual dSPL, 12Hr, Elec, Efan, Cfan, dFin, CoFF