2 Troubleshooting Procedures

2.3 Power Supply Troubleshooting

Check 1 Compare the patterns in the hexadecimal error code to the tables below.

‰ DC IN

Error code

Meaning

 

 

10h

AC Adaptor output voltage is over 16.5 V.

 

 

11h

Advanced Port Replicator output voltage is over 16.5 V.

 

 

12h

Current from the DC power supply is over the limit (15.4 A).

 

 

13h

Current from the DC power supply is over the limit (0.5 A), when there

 

is no load.

14h

Current sensing IC is not normal, when there is no load.

 

 

‰ Main Battery

Error code

Meaning

 

 

20h

Over voltage has been detected.

 

 

21h

Main battery charge current is over 15.4 A.

 

 

22h

Main battery discharge current is over 0.5 A, when there is no load.

 

 

23h

Main battery charge current is over 4.3 A, when the AC adapter is not

 

directly connected.

 

 

24h

Current sensing IC is not normal, when there is no load.

 

 

25h

Main battery charge current is over 0.3 A.

 

 

‰ 2nd Battery

Error code

Meaning

 

 

30h

Over voltage has been detected.

 

 

31h

2nd battery charge current is over 15.4 A.

 

 

32h

2nd battery discharge current is over 0.5 A, when there is no load.

 

 

33h

2nd battery charge current is over 4.3 A, when the AC adapter is not

 

directly connected.

34h

Current sensing IC is not normal, when there is no load.

 

 

35h

2nd battery charge current is over 0.3 A.

 

 

‰ S3V output

Error code

Meaning

 

 

40h

S3V voltage is 3.14 V or under, when the computer is powered on/off.

 

 

45h

S3V voltage is 3.14 V or under, when the computer is booting up.

 

 

2-10

Satellite A40 Maintenance Manual (960-458)