4 Replacement Procedures

4.26 Fluorescent lamp

10.Stick the protection cover G (B), protection cover S (A), fixing tape (C) and fixing tape for lead wire (D).

Fit the cover according to the outline of the screw.

(A)

(C)(B)

(D)

0 to 1 mm

Do not make the tape over the top of the module.

0 to 0.5 mm

The tape MUST NOT appear on the display.

Stick the tape according to the outline of the LCD module. Make sure the tape does not appear on the side of the module.

Figure 4-120 Replacing 15.0 Inch Sharp fluorescent lamp (XGA) (23)

4-126

Satellite A40 Maintenance Manual (960-458)

Page 334
Image 334
Toshiba A40 manual Replacing 15.0 Inch Sharp fluorescent lamp XGA