4 Replacement Procedures

4.26 Fluorescent lamp

7.Bend the TCP attaching to the source board and secure it with two screws. Then bend the TCP attaching to the gate board with two screws and insert the FPC (G) into the connector of the source board.

Do not hold the edge.

Do not hold the edge.

Figure 4-146 Replacing 15.0 Inch Sharp fluorescent lamp (SXGA+) (18)

Check the condition after mating. *Check the condition of the concave portion of

the FPC and the outline of the connector. *Insert the FPC to the end. There shall be no

out of position in θ. *Lock surely the connector.

Fold the source board.

Fit the pin and the hole.

Screw

Poor mating: Failure

Out-of-position in θ: Failure

Screw

Screw

Fit the pin and the hole.

(G)

Fit the pin and the hole.

Screw tightening torque: 0.9kgcm

Do not cover the projection.

Fold the gate board.

Screw

Figure 4-147 Replacing 15.0 Inch Sharp fluorescent lamp (SXGA+) (19)

4-144

Satellite A40 Maintenance Manual (960-458)

Page 295
Image 295
Toshiba A40 manual Replacing 15.0 Inch Sharp fluorescent lamp SXGA+