Desa FMH26TN Cleaning And Maintenance, Burner Flame Pattern, Cabinet, Air Passageways, Exterior

Models: FMH26TN 14 FMH26TN

1 28
Download 28 pages 8.4 Kb
Page 19
Image 19
BURNER FLAME PATTERN

OWNER’S MANUAL

INSPECTING

BURNER

Continued

BURNER FLAME PATTERN

Figure 33 shows a correct burner flame pattern. Figure 34 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tip- ping. It also shows the flame consistently higher than one inch above the log.

Note: When using the fireplace the first time, the flame will be orange for approxi- mately one hour until the log cures.

If burner flame pattern is incorrect, as shown in Figure 34

turn fireplace off (see To Turn Off Gas to Appliance, page 18)

see Troubleshooting, pages 20 through 22

Top of Flame About

One Inch Above Log

Figure 33 - Correct Burner Flame Pattern

Figure 34 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning.

CABINETCAUTION: You must keep con- trol areas, burner, and circulating air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fiedserviceperson. Fireplacemay need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 35).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 36). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 35 - Injector Holder On Outlet Burner Tube

Pilot Air

Inlet Hole

Figure 36 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

107105

19

Page 19
Image 19
Desa FMH26TN Cleaning And Maintenance, Burner Flame Pattern, Cabinet, Air Passageways, Exterior, Inspecting Burner