![](/images/new-backgrounds/1027919/2791923x1.webp)
DESA INTERNATIONAL
VENT-FREE NATURAL GAS STOVE HEATER
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
• piping (check local codes) | |
• sealant (resistant to LP gas) | |
• | equipment shutoff valve * |
• | test gauge connection * |
The gas inlet connection for the stove heater is located on the lower
19.Make sure gas log heater is secured to the stove cavity assembly.
WARNING: Never connect heater to private
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 20, SVYD18NR and FSVYD18NR series, or Figure 21, SVYD18N and FSVYD18 series).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliances.
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
• | sediment trap |
• | tee joint |
• | pipe wrench |
*A CSA
Back View
Back Stove
Panel
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
Gas Control
3" Minimum
Approved Flexible Gas Hose (if allowed by local codes)
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Tee Joint
Pipe Nipple SedimentTrap
Cap
Figure 20 - Gas Connection (SVYD18NR and FSVYD18NR Series)
Product
Identification
Label
| Side View |
|
Front of | Gas Inlet | Gas |
Log | ||
Stove | Connection | Heater |
Unit | Access |
|
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Sediment Tee Joint |
| |
Trap | Pipe |
|
Nipple |
| |
| 3" Minimum | |
| Cap | |
|
|
CSA
Equipment Shutoff Valve
With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Gas
Regulator
Figure 19 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
Figure 21 - Gas Connection (SVYD18N and FSVYD18N Series)
*Purchase the optional CSA
**Minimum inlet pressure for purpose of input adjustment.
12 | 104461 |