13.Replace log base assembly in fireplace. Feed flexible gas sup- ply line into fireplace base area while replacing log base as- sembly. Make sure the entire flexible gas line is in fireplace base area. Note: If firebrick is installed, make sure the back of the firebox bottom slides under the rear panel of the firebrick (lift the firebrick up if necessary).

IMPORTANT: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

14.Reattach log base assembly to fireplace with screws removed in step 3, page 5. Note: Discard the remaining hardware items.

15.Install logs and fireplace screen per instructions in operating manual provided with fireplace.

WARNING: Failure to position the parts in accor- dance with supplied diagrams or failure to use only parts specifically approved with this heater may result in damage or personal injury.

16.Connect gas supply to fireplace per instructions in operating manual provided with fireplace.

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

OPERATING THE BLOWER

Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire. Note: Periodically check the louvers of the fire- box and remove any dust, dirt, or other obstructions.

INSTALLING BLOWER ACCESSORY IN FREESTANDING STOVE SERIES SDV, MSD, MSTD, CDV OR CSDBN

IMPORTANT: Read all installation instructions be- fore installing blower.

NOTICE: Shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this.

INSTALLING THE BLOWER

1.Remove 4 hex bolts securing rear cover to back of stove body (see Figure 22).

2.Separate bottom cover from rear cover by loosening the 8 mounting screws (see Figure 22).

3.Align the holes in the top mounting tabs of blower with the holes in wall of rear cover (see Figure 23, page 9). Using the 4 screws provided, mount blower and tighten screws securely.

4.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor.

5.Attach green ground wire from power cord to blower hous- ing using screw provided (see Figure 23, page 9). Tighten screw securely.

Rear Cover

Screw

(Note: Stove Body May Vary by Model)

Figure 22 - Removing/ Installing Rear Cover

For morevisit www..com

108319-01B

Page 8
Image 8
Desa Ga3750a installation instructions Installing the Blower

Ga3750a specifications

Desa GA3750A is a state-of-the-art technological solution designed for enhanced gas management in various applications. Built with user-friendly features and advanced mechanics, the GA3750A stands out in the market for its efficiency and reliability.

One of the main features of the Desa GA3750A is its efficient gas control mechanism. It is equipped with a high-precision pressure regulator that ensures stable and consistent gas flow. This mechanism is essential for applications requiring precise gas consumption, such as industrial processes and commercial kitchens. It minimizes wastage while maximizing performance efficiency.

The GA3750A utilizes cutting-edge materials, ensuring durability and longevity. Its corrosion-resistant construction not only prolongs the lifespan of the device but also makes it suitable for use in harsh environments. Whether in high-humidity areas or exposed to corrosive substances, the GA3750A maintains its integrity, delivering reliable service over time.

In terms of technology, the GA3750A incorporates smart monitoring systems that provide real-time data on gas usage. This feature allows users to track consumption patterns, offering insights that can lead to optimized operations and cost savings. The integration of IoT connectivity means that this device can be easily connected to advanced monitoring systems, enabling remote access and control.

Moreover, safety is prioritized in the design of the GA3750A. Equipped with multi-layer safety features, it includes automatic shut-off valves and leak detection sensors. In the event of a malfunction or detected leak, these safety measures activate to prevent potential hazards, ensuring that users can operate with peace of mind.

The GA3750A is also designed for ease of installation and maintenance. Its modular construction facilitates simple setup, and the components can be easily accessed for routine checks or repairs. This consideration for user convenience significantly reduces downtime and maintenance costs.

Overall, the Desa GA3750A embodies a blend of advanced technology and practical features, making it an essential tool for gas management in industrial and commercial settings. With its focus on efficiency, durability, and safety, the GA3750A is a market leader that meets the demands of modern applications effectively.