TROUBLE- | WARNING | |
SHOOTING | ||
Turn off and unplug heater and let cool before servicing. | ||
Note: All troubleshooting | Unless you need gas supply for testing, shut off manual | |
shutoff valve before servicing. Only a qualified service | ||
items are listed in order of | person should service and repair heater and venting | |
operation. | system. | |
|
|
|
|
|
|
|
| CAUTION |
|
|
|
|
|
|
|
|
| Never use a wire, needle, or similar object to clean pilot. |
|
|
| ||||
|
|
|
| This can damage pilot. |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
| OBSERVED | POSSIBLE |
|
|
|
|
| |||
|
| PROBLEM | CAUSE | REMEDY | |||||||
|
|
|
|
|
|
|
|
|
| ||
|
| When ignitor button is | 1. | Incorrect spark gap. | 1. | Adjust spark gap to 1/16". | |||||
|
| pressed, there is no | 2. | Ignitor electrode posi- | 2. | Replace ignitor. | |||||
|
| spark at pilot. |
| tioned wrong. |
|
|
|
|
| ||
|
|
|
|
| 3. | Ignitor electrode broken. | 3. | Replace ignitor. | |||
|
|
|
|
| 4. | Ignitor electrode not con- | 4. | Reconnect ignitor cable. | |||
|
|
|
|
|
| nected to ignitor cable. |
|
|
|
|
|
|
|
|
|
| 5. | Ignitor cable pinched or | 5. | Free ignitor cable if | |||
|
|
|
|
|
| wet. |
| pinched by any metal or | |||
|
|
|
|
|
|
|
| tubing. Keep ignitor | |||
|
|
|
|
|
|
|
| cable dry. | |||
|
|
|
|
| 6. | Piezo ignitor nut is loose. | 6. | Tighten nut holding piezo | |||
|
|
|
|
|
|
|
| ignitor to heater cabinet. | |||
|
|
|
|
|
|
|
| Nut is located inside | |||
|
|
|
|
|
|
|
| heater cabinet at top. | |||
|
|
|
|
| 7. | Broken or frayed ignitor | 7. | Replace ignitor cable. | |||
|
|
|
|
|
| cable. |
|
|
|
|
|
|
|
|
|
| 8. | Loose ignitor cable. | 8. | Reconnect ignitor cable. | |||
|
|
|
|
| 9. | Bad piezo ignitor. | 9. | Replace piezo ignitor. | |||
|
|
|
|
|
|
|
| ||||
|
| When ignitor button is | 1. Gas supply turned off or | 1. | Turn on gas supply or | ||||||
|
| pressed, there is spark |
| manual shutoff valve |
| open manual shutoff | |||||
|
| at pilot but no igni- |
| closed. |
| valve. | |||||
|
| tion. | 2. | Control knob not in PI- | 2. | Turn control knob to PI- | |||||
|
|
|
|
|
| LOT position. |
| LOT position. | |||
|
|
|
|
| 3. | Control knob not pressed | 3. | Press in control knob | |||
|
|
|
|
|
| in while in PILOT posi- |
| while in PILOT position. | |||
|
|
|
|
|
| tion. |
|
|
|
|
|
|
|
|
|
| 4. | Air in gas lines when in- | 4. | Continue holding down | |||
|
|
|
|
|
| stalled. |
| control knob. Repeat ig- | |||
|
|
|
|
|
|
|
| niting operation until air | |||
|
|
|
|
|
|
|
| is removed. | |||
|
|
|
|
| 5. | Pilot is clogged. | 5. | Clean pilot (see Cleaning | |||
|
|
|
|
|
|
|
| and Maintenance, page | |||
|
|
|
|
|
|
|
| 25) or replace pilot as- | |||
|
|
|
|
|
|
|
| sembly. | |||
|
|
|
|
| 6. | Gas regulator setting is | 6. | Replace control valve. | |||
|
|
|
|
|
| not correct. |
|
|
|
|
|
26 |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100353 |