TROUBLE- | WARNING | |
SHOOTING |
| |
If you smell gas | ||
Continued | • Shut off gas supply. | |
• Do not try to light any appliance. | ||
|
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
OBSERVED | POSSIBLE |
|
|
|
|
|
|
|
| |
PROBLEM | CAUSE | REMEDY |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||||
Heater produces a | 1. | Metal expanding while | 1. | This is | common with | |||||
clicking/ticking noise |
| heating or contracting |
| most heaters. If noise is | ||||||
just after burner is lit |
| while cooling. |
| excessive, contact quali- | ||||||
or shut off. |
|
|
| fied service person. | ||||||
|
|
|
|
|
|
|
| |||
Heater produces un- | 1. | Heater burning vapors | 1. | Ventilate room. Stop us- | ||||||
wanted odors. |
| from paint, hair spray, |
| ing odor causing prod- | ||||||
|
| glues, etc. |
| ucts while heater is run- | ||||||
|
| Gas leak. See Warn- |
| ning. |
|
|
|
|
|
|
| 2. | 2. | Find and | correct all | ||||||
|
| ing statement at top |
| leaks (see Checking Gas | ||||||
|
| of page. |
| Connections, page 13). | ||||||
|
|
|
|
|
|
| ||||
Heater shuts off in use. | 1. | Heater not venting cor- | 1. | Check venting system. | ||||||
|
| rectly. Vent safety |
| If damaged or blocked, | ||||||
|
| switch shuts off heater. |
| repair. If venting system | ||||||
|
|
|
| is OK, | have qualified | |||||
|
|
|
| service | person replace | |||||
|
|
|
| vent safety switch, wire | ||||||
|
|
|
| harness, | or thermo- | |||||
|
|
|
| couple interrupter. | ||||||
| 2. | Low line pressure. | 2. | Contact local natural gas | ||||||
|
|
|
| company. |
|
|
|
|
| |
| 3. | Pilot partially clogged. | 3. | Clean pilot (see Clean- | ||||||
|
|
|
| ing and Maintenance, | ||||||
|
|
|
| page 25). |
|
|
|
|
| |
|
|
|
|
|
|
|
| |||
Gas odor even when | 1. | Gas leak. See Warn- | 1. | Find and | correct all | |||||
control knob is in OFF |
| ing statement at |
| leaks (see Checking Gas | ||||||
position. |
| top of page. |
| Connections, page 13). | ||||||
| 2. | Control valve damaged. | 2. | Replace control valve. | ||||||
|
|
|
|
|
| |||||
Gas odor during com- | 1. | Foreign matter be- | 1. | Take apart gas tubing | ||||||
bustion. |
| tween control valve and |
| and remove foreign mat- | ||||||
|
| burner. |
| ter. |
|
|
|
|
|
|
| 2. | Gas leak. See Warn- | 2. | Find and | correct all | |||||
|
| ing statement at |
| leaks (see Checking Gas | ||||||
|
| top of page. |
| Connections, page 13). | ||||||
| 3. | Foreign fumes in area | 3. | Ventilate | area around | |||||
|
| of heater being drawn |
| heater | to | remove any | ||||
|
| through burner com- |
| foreign fumes. | ||||||
|
| bustion. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 29 |
100353