TROUBLE- | OBSERVED | POSSIBLE |
|
|
|
|
|
|
|
|
| ||
PROBLEM | CAUSE |
|
|
| REMEDY |
|
|
| |||||
SHOOTING |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Pilot lights but flame | 1. | Manual shutoff | valve | 1. | Fully open manual shut- | ||||||||
Continued | goes out when |
| not fully open. |
|
|
| off valve. |
|
|
| |||
| control knob is | 2. | Control knob not fully | 2. | Press | in control knob | |||||||
| released. |
| pressed in. |
|
|
|
| fully. |
|
|
|
| |
|
| 3. | Control | knob | not | 3. | After pilot lights, keep | ||||||
|
|
| pressed in long enough. |
| control knob pressed in | ||||||||
|
| 4. | Safety interlock system |
| 30 seconds. |
|
|
| |||||
|
| 4. | Wait | one minute | for | ||||||||
|
|
| has been triggered. |
|
| safety interlock system | |||||||
|
| 5. | Thermocouple connec- |
| to reset. Repeat ignition. | ||||||||
|
| 5. | Hand tighten until snug, | ||||||||||
|
|
| tion | loose at control |
| then tighten | 1/4 | turn | |||||
|
|
| valve. |
|
|
|
| more. |
|
|
|
| |
|
| 6. | Pilot flame not touching | 6. | A) Contact | qualified | |||||||
|
|
| thermocouple, | which |
| service person to prop- | |||||||
|
|
| allows thermocouple to |
| erly adjust pilot flame | ||||||||
|
|
| cool, | causing | pilot |
| B) Contact local natural | ||||||
|
|
| flame to go out. This |
| gas company. |
|
|
| |||||
|
|
| problem | could | be |
| C) Clean pilot (see |
| |||||
|
|
| caused by any or all of |
| Cleaning and Mainte- | ||||||||
|
|
| the following: |
|
|
| nance, page 25) or |
| |||||
|
|
| A) Improperly adjusted |
| replace pilot assembly. | ||||||||
|
|
| pilot flame |
|
|
|
|
|
|
|
| ||
|
|
| B) Low gas pressure |
|
|
|
|
|
| ||||
|
|
| C) Dirty or partially |
|
|
|
|
|
| ||||
|
|
| clogged pilot |
|
|
|
|
|
|
|
| ||
|
| 7. | Thermocouple | dam- | 7. | Replace thermocouple. | |||||||
|
|
| aged. |
|
|
|
|
|
|
|
|
|
|
|
| 8. | Control valve damaged. | 8. | Replace control valve. | ||||||||
|
|
|
|
|
|
|
| ||||||
| Burner does not light | 1. | Safety interlock system | 1. | Fully | depress | control | ||||||
| after pilot is lit. |
| has been inadvertently |
| knob | in any |
| position | |||||
|
|
| triggered. |
|
|
|
| other than pilot and re- | |||||
|
|
|
|
|
|
|
|
| lease. Wait one minute | ||||
|
|
|
|
|
|
|
|
| for safety interlock sys- | ||||
|
|
|
|
|
|
|
|
| tem to reset. Repeat igni- | ||||
|
| 2. | Burner | orifice | is |
| tion. |
|
|
|
| ||
|
| 2. | Clean burner (see Clean- | ||||||||||
|
|
| clogged. |
|
|
|
| ing and Maintenance, | |||||
|
|
|
|
|
|
|
|
| page | 25) or | replace | ||
|
| 3. | Burner orifice diameter |
| burner orifice. |
|
|
| |||||
|
| 3. | Replace burner orifice. | ||||||||||
|
|
| is too small. |
|
|
|
|
|
|
|
| ||
|
| 4. | Inlet gas pressure is too | 4. | Contact local | natural | |||||||
|
|
| low. |
|
|
|
|
| gas company. |
|
|
| |
|
|
|
|
|
|
| |||||||
| Delayed ignition of | 1. | Manifold pressure is too | 1. | Contact local | natural | |||||||
|
| low. |
|
|
|
|
| gas company. |
|
|
| ||
| burner. |
|
|
|
|
|
|
|
|
| |||
| 2. | Burner | orifice | is | 2. | Clean | burner | (see | |||||
|
| ||||||||||||
|
|
| clogged. |
|
|
|
| Cleaning and Mainte- | |||||
|
|
|
|
|
|
|
|
| nance, page 25) or re- | ||||
|
|
|
|
|
|
|
|
| place burner orifice. |
Continued
100353
27