Finish Mounting

Finish Mounting

Align the fixture base plate, gasket, and the junction box holes. Secure with mounting screws that fit your junction box.

If not installed on a weatherproof box or if an adaptor plate was used, caulk between the base plate and mounting surface with sili- cone weather sealant.

To avoid water damage and electrical shock, keep lamp holders aimed below horizontal.

Specifications

 

 

Range

Up to 100 feet (30.5 m) with

 

Range Boost On; up to 70

 

feet (21 m) with Range Boost

 

Off. (Varies with surround-

 

ing temperature).

 

Sensing Angle

Up to 270°

 

 

Sensor Load Capacity .

Up to 1000 Watts (8.3 amps)

 

Maximum, Incandescent

Power Requirements . .

120 VAC, 60 Hz

 

Operating Modes

TEST,

AUTO

and

 

MANUAL OVERRIDE

 

Time Delay

1 , 5, 20 minutes

 

Sensitivity

Adjustable

 

 