CHECKING GAS CONNECTIONS

INSTALLATION

Continued

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/ equipment shutoff valve (see Figure 26).

5.Check all gas connections for leaks. See Checking Gas Connections.

6.Replace branch support back into fireplace. Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reattach branch support to fireplace with screws removed in step 2 on page 17.

To Fireplace

Equipment Shutoff

Gas Regulator

Valve Provided by

 

Installer

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.

Disconnect appliance with its appliance main

 

gas valve (control valve) and equipment

 

shutoff valve from gas supply piping system.

 

Pressures in excess of 1/2 psig will damage

 

heater regulator.

2.

Cap off open end of gas pipe where equipment

 

shutoff valve was connected.

3.

Pressurize supply piping system by either

 

opening propane/LP supply tank valve for

 

propane/LP gas or opening main gas valve

 

located on or near gas meter for natural gas

 

or using compressed air.

4.

Check all joints of gas supply piping system.

 

Apply a noncorrosive leak detection fluid to

Flexible Gas Line from Manual background Fireplace Gas Regulator Provided with Fireplace

PROPANE/LP

To External

Regulator

NATURAL

To Gas Supply

 

gas joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment shutoff valve

 

to gas supply. Check reconnected fittings for

 

leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

Figure 26 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

CHECKING GAS CONNECTIONS

Manual background WARNING: Test allgas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

Manual background WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Manual background CAUTION: Make sure exter- nal regulator has been installed between propane/LPsupply and fireplace. See guidelines under Connecting to Gas Supply, page 16.

1.Close equipment shutoff valve (see Fig- ure 27).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter for natural or propane/LP supply to equipment shutoff valve (see Figures 28 and 29, page 19). Ap- ply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

Open

Shutoff

 

Valve

 

 

Closed

Figure 27 - Equipment Shutoff Valve