Desa HDVF3018P, HDVF3018N Continued, Mantel Clearances, Marble, Tile, etc. Above Fireplace

Models: HDVF3018N HDVF3018P

1 28
Download 28 pages 39.17 Kb
Page 10
Image 10
Figure 5 - Heat Resistant Material (Slate,

INSTALLATION

Continued

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have non- combustible material behind it. Noncombustible material must extend at least 8" up (for all models). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and 6 and Figure 7 on page 11 for minimum

Noncombustible

Requirements for

Material

Safe Installation

Distance (A)

 

 

 

 

 

 

 

 

 

12" or more

Noncombustible material

 

okay.

Between 8"

Noncombustible material

and 12"

okay.

Less than 8"

Noncombustible material

 

must be extended to at

 

least 8". See Between 8"

 

and 12", above. If you

 

cannot extend material,

 

you must operate heater

 

with flue damper open.

 

 

 

 

 

Heat Resistant

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

(A)

 

 

 

 

 

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp

Accessory for Vented Operation, page 11.

Mantel Clearances

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances in Figure 6 you will need a hood.

Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clearance

When Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7, page 11 when using hood.

NOTICE: Surface temperatures ofadjacentwallsandmantelsbe- comehotduringoperation.Walls and mantels above the firebox may become hot to the touch. If installed properly, these tem- peratures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

 

10"

 

Mantel Shelf

 

 

 

 

 

 

 

8"

 

 

 

Underside of

 

6"

 

 

 

Mantel Shelf

 

 

 

 

 

 

2 1/2"

 

 

 

 

Minimum

 

 

 

 

All minimum

Noncombustible

 

 

 

 

distances are

Material

(A)

 

 

 

in inches

 

8"

8"

14"

17"

20"

 

 

 

 

 

Top of

 

 

 

 

 

Fireplace

 

Minimum

 

Distances to

Opening

 

Noncombustible

Underside of

 

 

Material Height

Mantel

 

Figure 6 - Minimum Mantel Clearances

Without Using Hood

10

www.desatech.com

119421-01A

Page 10
Image 10
Desa HDVF3018P Continued, Mantel Clearances, Marble, Tile, etc. Above Fireplace, Accessory for Vented Operation, page