16

OPERATING HEATER

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Manual Lighting Procedure

Hand-Held Remote Operation

OPERATING HEATER

Continued

8.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

9.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

10.Slightly push in and turn control knob counterclockwise to the ON position.

11.Press the on/off key on the remote control to turn on appli- ance main burner. Wait at least 5 seconds before setting desired flame height.

12.Press the up or down key until the small triangle is to the left of large flame icon at the top of LCD display (see Figure 29). Press the left or right key to set the desired flame height.

13.Replace control cover log (see Figure 26, page 15).

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 7 under Lighting Instructions, page 15.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions in column 1.

HAND-HELD

REMOTE OPERATION

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, page 15.

When the appliance and the remote control are switched off, the house icon with the room temperature will be displayed. When the remote control is turned on, other icons will be visible and the main burner of the appliance will turn on.

1.Turn control knob clockwise to the ON position (see Figure 25, page 15).

2.Press the ON button on remote control (see Figure 29). Wait 5 seconds to send a command to appliance.

Note: An acoustic signal will be heard that confirms the recep- tion of the command sent from the remote control.

Pilot Burner

Ignitor

Pilot Burner

Ignitor

Electrode

 

Electrode

 

 

Figure 27 - Pilot (Propane/LP) Figure 28 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Press on/off key on remote control and turn control knob

clockwise to the OFF position (see Figure 25, page 15).

Shutting Off Burners Only (pilot stays lit)

Press the on/off key on remote control or turn control knob

clockwise to the PILOT position.

Small Triangle

Icon (Function

Indicator)

Flame Height

Indicator

Thermometer

Icon

Clock Icon

Left and Right

Keys Increase

and Decrease

Set Points

On/Off Button

LCD Display

Room Temperature Display

(°F or °C)

Sleep Timer

Display

Lock-Out

Indicator

Low Battery

Indicator

Up and Down

Keys Select

Available

Functions

Figure 29 - Remote Control

For..com

111515-01C

Page 16
Image 16
Desa LDL3930NR Manual Lighting Procedure, HAND-HELD Remote Operation, To Turn OFF GAS To Appliance, Shutting Off Heater

LDL3924PR, LDL3930NR, LDL3930PR specifications

Desa LDL3924PR, LDL3930PR, and LDL3930NR represent a comprehensive range of innovative HVAC solutions. Each model is engineered to provide efficient heating and cooling in residential and commercial applications, ensuring optimal thermal comfort throughout the year.

The LDL3924PR model stands out with its advanced inverter technology, enabling variable speed operation that adjusts according to the heating or cooling demand. This not only enhances energy efficiency but also promotes quieter operation, making it ideal for residential settings. By seamlessly adapting to temperature fluctuations, users experience consistent comfort without the energy spikes often associated with conventional systems.

Similarly, the LDL3930PR model incorporates robust features such as high SEER (Seasonal Energy Efficiency Ratio) ratings, which indicate superior energy efficiency during cooling cycles. This model is specifically designed to work efficiently even in extreme weather conditions, maintaining performance in both high temperatures and colder climates. The extended lifespan of the compressor is another hallmark, thanks to its advanced protection mechanisms and durable construction materials.

The LDL3930NR is particularly notable for its eco-friendly refrigerant, which significantly reduces greenhouse gas emissions while maintaining excellent cooling efficiency. This model focuses on sustainable cooling solutions, aligning with global initiatives to combat climate change. With a sleek design, it blends seamlessly into modern spaces, making it a popular choice for aesthetic-conscious consumers.

All three models boast user-friendly interfaces, enabling easy control and customization of settings. Smart capabilities are integrated into the design, allowing for remote access and monitoring via mobile applications. This feature empowers users to adjust settings from anywhere, optimizing energy usage and ensuring comfort is always within reach.

In addition, these models include multi-stage filtration systems that not only enhance indoor air quality but also reduce allergens and pollutants. With low operating noise levels and aesthetically pleasing designs, the Desa LDL series is capable of enhancing any environment while promoting energy efficiency.

Whether for residential or commercial use, Desa's LDL3924PR, LDL3930PR, and LDL3930NR models exemplify the perfect integration of technology, efficiency, and user-centric design principles, making them top choices in the modern HVAC market.