2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

LOCAL CODES

3

UNPACKING

3

PRODUCT IDENTIFICATION

4

PRODUCT FEATURES

4

AIR FOR COMBUSTION AND VENTILATION

4

INSTALLATION

7

OPERATING HEATER

15

INSPECTING BURNERS

17

CLEANING AND MAINTENANCE

18

TROUBLESHOOTING

19

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

.............. 22

SPECIFICATIONS

24

REPLACEMENT PARTS

24

WIRING DIAGRAM

24

SERVICE HINTS

24

TECHNICAL SERVICE

24

OWNER’S REGISTRATION FORM

25

ACCESSORIES

27

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes very hot when run- ning heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carefully supervise young children when they are in the room with heater. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

For..com

111515-01C

Page 2
Image 2
Desa LDL3924PR, LDL3930PR, LDL3930NR installation manual Table of Contents, Safety Information

LDL3924PR, LDL3930NR, LDL3930PR specifications

Desa LDL3924PR, LDL3930PR, and LDL3930NR represent a comprehensive range of innovative HVAC solutions. Each model is engineered to provide efficient heating and cooling in residential and commercial applications, ensuring optimal thermal comfort throughout the year.

The LDL3924PR model stands out with its advanced inverter technology, enabling variable speed operation that adjusts according to the heating or cooling demand. This not only enhances energy efficiency but also promotes quieter operation, making it ideal for residential settings. By seamlessly adapting to temperature fluctuations, users experience consistent comfort without the energy spikes often associated with conventional systems.

Similarly, the LDL3930PR model incorporates robust features such as high SEER (Seasonal Energy Efficiency Ratio) ratings, which indicate superior energy efficiency during cooling cycles. This model is specifically designed to work efficiently even in extreme weather conditions, maintaining performance in both high temperatures and colder climates. The extended lifespan of the compressor is another hallmark, thanks to its advanced protection mechanisms and durable construction materials.

The LDL3930NR is particularly notable for its eco-friendly refrigerant, which significantly reduces greenhouse gas emissions while maintaining excellent cooling efficiency. This model focuses on sustainable cooling solutions, aligning with global initiatives to combat climate change. With a sleek design, it blends seamlessly into modern spaces, making it a popular choice for aesthetic-conscious consumers.

All three models boast user-friendly interfaces, enabling easy control and customization of settings. Smart capabilities are integrated into the design, allowing for remote access and monitoring via mobile applications. This feature empowers users to adjust settings from anywhere, optimizing energy usage and ensuring comfort is always within reach.

In addition, these models include multi-stage filtration systems that not only enhance indoor air quality but also reduce allergens and pollutants. With low operating noise levels and aesthetically pleasing designs, the Desa LDL series is capable of enhancing any environment while promoting energy efficiency.

Whether for residential or commercial use, Desa's LDL3924PR, LDL3930PR, and LDL3930NR models exemplify the perfect integration of technology, efficiency, and user-centric design principles, making them top choices in the modern HVAC market.