20
TROUBLESHOOTING
TROUBLESHOOTING
Continued
| OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY |
| ||
| Burner does not light after ODS/pilot is lit | 1. | Inlet gas pressure is too low | 1. | Contact local natural or propane/LP gas | |
|
| 2. | Burner orifice(s) clogged |
| company | |
|
| 2. Clean burner(s) (see Cleaning and Mainte- | ||||
|
| 3. | Thermopile leads disconnected or im- |
| nance, page 18) or replace burner orifice | |
|
| 3. | Reconnect leads (see Wiring Diagram, | |||
|
|
| properly connected |
| page 24) | |
|
| 4. | Burners will not come on in remote po- | 4. | Replace battery in | |
|
|
| sition |
| receiver | |
|
|
|
|
|
|
|
| Delayed ignition of one or both burners | 1. | Manifold pressure is too low | 1. | Contact local natural or propane/LP gas | |
|
| 2. | Burner orifice(s) clogged |
| company | |
|
| 2. | Clean burner(s) (see Cleaning and Main- | |||
|
|
|
|
| tenance, page 18) or replace burner | |
|
|
|
|
| orifice(s) | |
|
|
|
|
|
|
|
| Burner backfiring during combustion | 1. | Burner orifice is clogged or damaged | 1. | Clean burner (see Cleaning and Mainte- | |
|
| 2. | Damaged burner |
| nance, page 18) or replace burner orifice | |
|
| 2. | Replace damaged burner | |||
|
| 3. | Gas regulator defective | 3. | Replace gas regulator | |
|
|
|
|
|
|
|
| Slight smoke or odor during initial operation | 1. | Not enough air | 1. | Check burner for dirt and debris. If | |
|
|
|
|
| found, clean burner (see Cleaning and | |
|
| 2. | Gas regulator defective |
| Maintenance, page 18) | |
|
| 2. | Replace gas control | |||
|
| 3. | Residues from manufacturing processes | 3. | Problem will stop after a few hours of | |
|
|
| and logs curing |
| operation | |
|
|
|
|
|
|
|
| Heater produces a whistling noise when | 1. | Turning control knob to HI position | 1. | Turn control knob to LO position and | |
| burners are lit |
| when burners are cold |
| let warm up for a minute | |
|
| 2. | Air in gas line | 2. | Operate burners until air is removed | |
|
|
|
|
| from line. Have gas line checked by lo- | |
|
| 3. | Air passageways on heater blocked |
| cal natural or propane/LP gas company | |
|
| 3. | Observe minimum installation clear- | |||
|
| 4. | Dirty or partially clogged burner |
| ances (see pages 8 through 10) | |
|
| 4. | Clean burners (see Cleaning and Mainte- | |||
|
|
| orifice(s) |
| nance, page 18) or replace burner orifice | |
|
|
|
|
|
|
|
| White powder residue forming within burner | 1. | When heated, vapors from furniture pol- | 1. | Turn heater off when using furniture | |
| box or on adjacent walls or furniture |
| ish, wax, carpet cleaners, etc. may turn |
| polish, wax, carpet cleaners, or similar | |
|
|
| into white powder residue |
| products | |
|
|
|
|
|
|
|
| Moisture/condensation noticed on windows | 1. | Not enough combustion/ventilation air | 1. | Refer to Air for Combustion and Venti- | |
|
|
|
|
| lation requirements (page 4) | |
|
|
|
|
|
|
|
| Dark residue on logs inside of their fireplace | 1. | Improper log placement | 1. | Properly locate logs (see Installing Logs, | |
| Note: After removing all causes of residue | 2. | Drafts or other air currents affecting |
| page 14) | |
| deposits, completely clean fireplace and ap- | 2. | Eliminate source of drafts around heater | |||
| pliance off residue before reusing appliance |
| flame pattern |
|
|
|
|
| 3. | Air holes at burner inlet blocked | 3. | Clean out air holes at burner inlet. Peri- | |
|
| 4. | Burner flame holes blocked |
| odically repeat as needed | |
|
| 4. | Remove blockage | |||
| For |
| . |
| .com |