Desa LFP33NRA Optional Remote Operation, To Turn OFF GAS To Appliance, Optional Blower Operation

Models: LFP33NRA

1 30
Download 30 pages 62.2 Kb
Page 17
Image 17

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

WARNING: Make sure the selector switch is in the OFF po-

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, pages 24 and 25). Follow instructions in- cluded with the remote control.

IMPORTANT: The thermostat is built into the hand-held remote. The remote should be kept several feet from the fire- place and should be pointed towards the fireplace. If placed too close to the fire- place, the remote will sense the room is too hot and turn the fireplace off.

sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor Electrode

Figure 37 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

• Turn control knob clockwise

 

to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

Thermostat Control Operation

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 16.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide thee selector switch to the REMOTE po- sition. Note: The burners may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit. Fol- low the instructions supplied with the remote control for additional features.

IMPORTANT: Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/ OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower right inside louver door.

The GA3650TA Series thermostat-con- trolled blower has a variable speed con- trol with an ON/OFF switch. The blower will start when the thermostat senses a sufficient increase in firebox temperature. The GA3750 Series variable speed blower also has an ON/OFF switch built into the variable speed control.

Note for GA3650TA Series Only: If you are using GA3650TA blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will con- tinue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.

Follow installation instructions included with the blower accessory.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-

 

ing Instructions, page 16.

2.

Depress control knob and light pilot

 

with match.

Flame Adjustment Knob

 

IH

 

P

 

 

F

IL

 

 

 

O

 

 

F

 

T

 

 

O

 

 

 

 

 

 

 

 

 

O

 

 

 

 

N

ON

 

 

 

 

LO

 

 

 

OFF

REMOTE

Control Knob in

3. Keep control knob pressed in for 30

seconds after lighting pilot. After 30

On Position

Selector Switch in Remote Position (Optional Remote Control)

seconds, release control knob. Now

follow step 9, page 16.

Figure 38 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

107063

17

Page 17
Image 17
Desa LFP33NRA installation manual Optional Remote Operation, To Turn OFF GAS To Appliance, Optional Blower Operation