LFP33NRA

UNVENTED NATURAL GAS FIREPLACE

WIRING DIAGRAM

Note: For proper operation of optional ac- cessories, the wires from the switch to the control must be connected exactly as shown.

OFF

ON

Thermopile

SPECIFICATIONS

LFP33NRA Remote Ready

Btu (Variable)

20,000/30,000

 

Type Gas

Natural Gas Only

Ignition

Piezo

 

Pressure Manifold

3.5" W.C.

 

Inlet Gas Pressure (in. of water)

 

 

 

Maximum

10.5"

 

Minimum*

5"

Shipping Weight

122 lbs.

 

* For input adjustment

 

 

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical service web site at www.desatech.com.

22

107063

Page 22
Image 22
Desa LFP33NRA installation manual Wiring Diagram, Specifications, Service Hints, Technical Service