Desa M36 Installation, Continued, COMBUSTION AIR KIT MODEL AK4 OPTIONAL, Appliance Enclosure

Models: M36 VM42

1 28
Download 28 pages 44.66 Kb
Page 16
Image 16
COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

16

INSTALLATION

Combustion Air Kit Model AK4 (Optional)

Appliance Enclosure

Installing Optional Glass Door Accessory

INSTALLATION

Continued

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 33). Pull the handle to open or push to close.

Figure 33 - Air Kit Handle Location CAUTION: Air inlet ducts are not to terminate in attic space.

Screen Pocket

Air Kit

Handle

Figure 33 - Air Kit Handle Location

APPLIANCE ENCLOSURE

Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking.

If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance. (see Figure 34).

Side

 

 

Side

Framing

 

 

Framing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caulk Here

Pack Insulation

Figure 34 - Sealing Between Appliance and Framing

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

APPLIANCE ENCLOSURE CAUTION: Use only glass doors certified for use with this appliance.

Note: Glass door may be heavy for some individuals. If this is the case, please request help from someone else.

The M36, VM36, M42 and VM42 B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 27). The glass panels may be ordered and installed anytime after the fireplace installation is complete.

Follow these steps to install left and right panels:

1.With the handle at the bottom, completely fold the panel on its hinges.

2.With the handle facing the center of the firebox opening, in- sert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 35).

3.Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the fire- box opening.

4.Tilt the glass assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 35).

Slide Top PinSpring Clip

Into Door Track

Insert Pin Into

Spring Clip

Insert Bottom

Pivot Pin Into

Pivot Plate and

Swing Door Into

Figure 34 - Sealing Between Appliance and Framing Vertical Position

Pivot Plate

Figure 35 - Installing Optional Glass Door

INSTALLING OPTIONAL GLASS DOOR ACCESSORYFigure 35 - Installing Optional Glass DoorManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundFor moreManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

108795-01E

Page 16
Image 16
Desa M36 Installation, Continued, COMBUSTION AIR KIT MODEL AK4 OPTIONAL, Appliance Enclosure, Air Kit Handle Location