12

INSTALLATION

Optional Wireless Hand-Held Remote Control Installation (Cont.) Gas Line Hook-Up

INSTALLATION

Continued

4.Connect wires to control circuit. Connect white wire to termi- nal marked TH/TP on control valve. Connect red wire to male blade connector provided at open end of safety circuit wiring (see Wiring Diagram, page 20).

5.Locate the battery clip mounted on the back of the receiver (see Figure 16).

6.Slide 9-volt battery (not included) through the clip. Note: Only use alkaline battery.

7.Attach the terminal wires to the battery (see Figure 16).

8.Replace refractory brick access panel.

 

9-Volt Battery

Battery

Receiver

Clip

 

Terminal

 

Wires

 

Figure 16 - Installing Battery in Receiver

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery (not included). Place bat- tery into the battery housing. Note: Only use alkaline battery.

3.Replace battery cover onto remote control unit.

GAS LINE HOOK-UP

WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.

WARNING: Before you proceed, make sure your gas supply is OFF.

A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 18.

In conformance with local codes, route a 1/2" NPT gas line towards the appliance coming in from any of the 3 directions shown in Figure 19.

CAUTION: Do not kink flexible gas line.

Typical Exterior Wall Gas

Shutoff

Shutoff Installation

Valve

Key

 

 

Extension

Figure 18 - Manual Shutoff Valve Installation

Battery

Remote

Cover

Control Unit

Terminal Wires

9-Volt Battery

Battery

Housing

1/2" NPT Incoming

Black Iron Gas Line

A

7"

7"

Alternate Gas Supply Through Sub-Floor

Flexible Gas Line

(1 Provided) Can

Be Extended Out

Either Side

B

Figure 17 - Installing Battery in Hand-Held Remote Control Unit

 

M36(B,H)/VM36(B,H)

M42(B,H)/VM42(B,H)

A

8 5/8" (219mm)

10 1/2" (267mm)

B

11" (279mm)

12 3/4" (324mm)

Figure 19 - Routing Incoming Gas Line

For morevisit www..com

108795-01E

Page 12
Image 12
Desa M36, VM42 installation manual GAS Line HOOK-UP, Installing 9-Volt Battery in Hand-Held Remote Control Unit

M36, VM42 specifications

Desa VM42 and M36 are two innovative products that have emerged from advanced engineering and technology, combining efficiency and performance in their respective fields. These machines are known for their unique features and characteristics that set them apart in the marketplace.

Desa VM42 is engineered for versatility and efficiency, making it an optimal choice for various applications. Its standout feature is its user-friendly interface, which allows operators to quickly adapt to using the machine, reducing the learning curve significantly. The VM42 is equipped with state-of-the-art automation technology, which facilitates precision engineering and minimal human error. This machine also boasts advanced thermal management systems that ensure consistent operation even under high loads, extending its lifespan and maintenance intervals.

On the other hand, the M36 model primarily emphasizes robust durability and power. The M36 comes with a heavy-duty chassis and is built to withstand harsh operating conditions, making it ideal for heavy industrial tasks. Its design includes high-strength materials and reinforced structural components, ensuring resilience against wear and tear. The M36 is equipped with a powerful engine that boosts productivity while maintaining fuel efficiency, a crucial aspect for reducing operational costs.

Both models leverage cutting-edge technologies such as IoT connectivity. This feature allows real-time monitoring and analysis of machine performance, making it easier for operators to handle maintenance proactively. Furthermore, the integration of smart sensors enhances safety by alerting users about potential issues before they escalate.

In terms of customization, Desa provides various options for both the VM42 and M36, allowing users to tailor specifications based on their specific needs. This flexibility ensures that customers can maximize the utility of these machines according to their operational requirements.

Another notable characteristic of both models is their environmental consciousness. Designed with eco-friendly technologies, they help in minimizing emissions and energy consumption. This aligns well with contemporary demands for sustainable practices in industrial operations.

In summary, Desa VM42 and M36 represent the pinnacle of modern engineering, combining user-friendly interfaces, robust designs, and innovative technologies to deliver exceptional performance in various applications. These machines not only enhance productivity but also support sustainable operational practices, making them leaders in their fields.