TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

23

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, etc. (See IMPORTANT

 

 

statement above)

 

2.

For propane/LP gas, low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while fireplace is running

2.Contact local propane/LP supplier

3.Locate and correct all leaks (see Gas Line Hook-Up, pages 12 and 13)

Gas odor even when control knob is in OFF 1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Gas

position

top of page

 

Line Hook-Up, pages 12 and 13)

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Gas Line Hook-Up, pages 12 and 13)

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

3.

Burner flame holes blocked

3.

Remove blockage or replace burner

 

4.

Improper venting or excessive blockage

4.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restrictions or obstruction

 

5.

Excessive amounts of embers and pan

5.

Clear excess embers until a minimum

 

 

material

 

gap of 1/2" remains under the grate

For more information, visit www.desatech.com

108795-01H

Page 23
Image 23
Desa M36, M42, VM36, VM42 installation manual Top, Gas leak. See Warning statement at