INSTALLING
Continued
CAUTION
WARNING ICON | G 001 |
Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
| A.G.A. |
| Manual Shutoff Valve |
From | With 1/8" NPT Tap* |
Gas Meter |
|
(5" W.C.** to |
|
10.5" W.C. |
|
Pressure) |
|
Tee Joint |
| |
Pipe | 3" Minimum | |
Nipple | ||
Cap |
| |
Sediment | Figure 13 - Gas Connection | |
Trap | ||
|
Approved Flexible Gas Hose (if allowed by local codes)
Gas
Regulator
*Purchase the optional A.G.A.
**Minimum inlet pressure for purpose of input adjustment.
CHECKING GAS CONNECTIONS
WARNING
WARNING ICON | G 001 |
Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.
WARNING
WARNING ICON | G 001 |
Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing gas Supply Piping system
Test Pressures In Excess Of 1/2 PSIG
1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
2.Cap off open end of gas pipe where manual shutoff valve was connected.
Continued
101308