Figure 34 - Positioning the Thermostat Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
Thermostat
Sensing Bulb
Figure 31 - Locating Thermostat Sensing Bulb on Masonry Fireplace
If you have a factory-built metal fireplace, see Figure 32 for location.
Thermostat
Sensing Bulb
Figure 32 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace
If your fireplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 33).
Thermostat
Sensing Bulb
Mounting Clip
Glass
Doors
Figure 33 - Installing Thermostat Sensing Bulb behind Glass Doors
OPTIONAL
POSITIONING
OF THERMOSTAT
SENSING BULB
For Masonry and
Factory-built
Metal Fireplace
Continued
5. The mounting clip must be a minimum of 3" from bottom of fireplace to prevent crimping of capillary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 34). Slide
the thermostat sensing bulb into the clip. |
|
IMPORTANT: Do not crimp capillary. | Thermostat |
| Sensing Bulb |
| |
Capillary | Mounting Clip |
| |
| Do Not Crimp Capillary |
30
101308