Desa NZ117, NZ119 Operating Heater, Continued, Low Battery Indicator, Childproof “Lock Out” - CP

Models: NZ103 NZ104 NZ119 NZ102 NZ100 NZ118 NZ117 NZ107 NZ116 NZ106 NZ101 NZ105

1 32
Download 32 pages 9.76 Kb
Page 18
Image 18
Low Battery Indicator

Operating Heater

Continued

To Activate the Program Mode

A short push (press and release) on TIME/ PROGRAM button will activate or deactivate program mode.

A long push (press and hold for more than 5 seconds) on TIME/PROGRAM button will enter into setting of program.

When the program mode is activated, the P-1 and P-2 icons and the word OFF will display on the screen. This means that unit turns off manual mode and enters into program mode. The unit will automatically check if current time is within pre-programmed ON time.

If current time is within program on time, unit will enter into thermo mode automatically and the word THERMO and set temperature digit(s) will display on screen.

When room temperature is below set tem- perature, unit will turn on and the word ON will replace the word OFF on the screen. The flame icon will also show on the screen. Unit will continue to operate in thermo mode until program off time is reached. When program off time is reached, unit will turn off and stay off until next program on time is reached or until user turns program mode off and turns unit on in manual or thermo mode.

If current time is not within program on time, unit will stay off until pre-programmed turn on time is reached. Pre-programmed time (P-1 and P-2 icons) will continue to display on screen indicating that unit is in program mode until set time is reached.

When program mode is deactivated, P-1 and P-2 icons and set temperature digit(s) will disappear from screen.

Factory Settings

The program function is preset at the follow- ing on and off times. These times will apply to every day of the week.

Program 1 (P1): Turn on at 7:00 AM. Turn off at 9:00 AM.

Program 2 (P2): Turn on at 5:00 PM. Turn off at 8:00 PM.

Setting a New Program

To change Program from the factory settings to new settings:

1.Press and hold TIME/PROGRAM button for more than 5 seconds to enter Set Program Mode.

2.P1 ON will flash. Push UP or DOWN but- ton until desired on time for Program 1 is reached. Press SET button.

3.P1 OFF will flash. Push UP or DOWN button until desired off time for Program 1 is reached. Press SET button.

4.P2 ON will flash. Push UP or DOWN but- ton until desired on time for Program 2 is reached. Press SET button.

5.P2 OFF will flash. Push UP or DOWN button until desired off time for Program 2 is reached. Press SET button.

The new program is now set and unit is in pro- gram mode. To take unit out of program mode, press and release TIME/PROGRAM button.

Note: In set program mode, set times will flash for 15 seconds. If the UP, DOWN or SET but- ton is not pressed within 15 seconds, system will automatically complete set up process and LCD Screen will revert to normal readouts. The first factory set temperature is at 45° F. Appliance will not turn on if room is not below the set temperature. If set temperature is at 70° F, appliance will come on only if room temperature is below 70° F.

Low Battery Indicator

A low BATTERY ICON on left side of LCD screen will appear when battery power has dropped significantly. At this time, approxi- mately two weeks of battery power remains until remote control may experience partial or complete loss of functions.

Childproof “Lock Out” – (CP)

This remote control includes a childproof lock out feature that allows the user to “lock out” operation of appliance from remote control.

1.To activate lock out feature, press and hold UP and TIME/PROGRAM buttons together for 5 seconds. Letters CP will appear in room temp window frame on LCD screen.

2.To disengage lock out, press and hold UP and TIME/PROGRAM buttons together for 5 seconds or more. Letters CP will disappear from LCD screen and remote control will return to its normal operating condition.

Note: If appliance is already operating in on or thermo modes engaging lock out will not cancel the operating mode. Engaging lock out only prevents manual operation of remote control. If in auto modes, the thermo operation will continue to operate normally. To totally lock out operation of remote control’s operating signals, remote control’s mode must be set to off.

18

www.desatech.com

118621-01B

Page 18
Image 18
Desa NZ117, NZ119, NZ118, NZ107 NZ116, NZ100 Operating Heater, Continued, Low Battery Indicator, Childproof “Lock Out” - CP