Desa NZ105, NZ119, NZ118, NZ100 Troubleshooting, Continued, Observed Problem Possible Cause, Remedy

Models: NZ103 NZ104 NZ119 NZ102 NZ100 NZ118 NZ117 NZ107 NZ116 NZ106 NZ101 NZ105

1 32
Download 32 pages 9.76 Kb
Page 24
Image 24
Cleaning and Mainte-

TROUBLESHOOTING

Continued

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Burner plaque(s) does not

1.

Plaque damaged

glow

2.

Inlet gas pressure is too

 

 

low

 

3.

Control knob set between

 

 

locked positions

1.Replace burner

2.Contact local natural or propane/LP gas company

3.Turn control knob until it locks at desired setting

Slight smoke or odor during

1.

Residues from manufac-

1.

Problem will stop after a

initial operation

 

turing processes

 

few hours of operation

 

 

 

 

 

Heater produces a clicking/

1.

Metal expanding while

1.

This is normal with most

ticking noise just after burner

 

heating or contracting

 

heaters. If noise is ex-

is lit or shut off

 

while cooling

 

cessive, contact qualified

 

 

 

 

service person

 

 

 

 

 

Remote does not function

1.

Pilot light not lit or control

1.

Check pilot light. Make

 

 

knob in wrong position

 

sure control knob is in the

 

 

 

 

ON position

 

2.

Batteries not installed cor-

2.

Check battery placement in

 

 

rectly. Batteries not in-

 

receiver and remote control.

 

 

stalled. Battery power is

 

Replace batteries in re-

 

 

low

 

ceiver and remote control

 

3.

Code settings on receiver

3.

Verify code settings

 

 

and remote control do not

 

 

 

 

match

 

 

 

4.

Receiver and remote con-

4.

Be sure reciever and re-

 

 

trol too far apart

 

mote control are within

 

 

 

 

20’-25’ operating range

 

 

 

 

 

White powder residue forming

1.

When heated, vapors from

1.

Turn heater off when us-

within burner box or on adja-

 

furniture polish, wax, car-

 

ing furniture polish, wax,

cent walls or furniture

 

pet cleaner, etc., may turn

 

carpet cleaners or similar

 

 

into white powder residue

 

products

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is

1.

Open window and/or door

operates)

 

available

 

for ventilation

 

2.

Low line pressure

2.

Contact local natural or

 

 

 

 

propane/LP gas company

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 21)

24

www.desatech.com

118621-01B

Page 24
Image 24