SAFETY INFORMATION UNPACKING

3

SAFETY INFORMATION

Continued

8.Turn fireplace off and let cool before servicing or repairing. Only a qualified service person should install, service, or re- pair this fireplace. Have fireplace inspected annually by a quali- fied service person.

9.You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 17.

11.Keep the area around your fireplace clear of combustible ma- terials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate.

14.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Ca- nadian Electrical Code, CSA C22.1.

15.Do not install fireplace directly on carpeting, vinyl tile, or any com- bustible material other than wood. The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace.

16.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.

17.Do not operate fireplace if any log is broken.

18.Do not use a blower insert, heat exchanger insert, or other ac- cessory not approved for use with this fireplace.

UNPACKING

The following items are packed inside the firebox. Remove before positioning firebox into framing.

Ceramic Log Pack - Shrink-wrapped on cardboard

Three (3) plastic bags containing lava rock, pan and ember materials

Rear Log (P325E/VP325E Models Only) - Remove the two plas- tic quick ties from around the burner and grate

Grate Stand - Lift off of burner pan

Check all items for any shipping damage. If damaged, promptly inform dealer or distributor where you bought the product.

Safely retain these items for later installation.

For more information, visit www.desatech.com

108794

Page 3
Image 3
Desa P325E(B), VP325E(B), P324E, VP324E, P325E, VP325E installation manual Unpacking

VP324E, P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B) specifications

Desa P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B), and VP324E are a series of advanced pumps designed to meet the diverse needs of industrial applications. These pumps are renowned for their efficiency, durability, and versatility, making them an ideal choice for various sectors such as manufacturing, chemical processing, and water management.

The main features of these pump models lie in their robust construction and innovative design. They are built using high-quality materials that ensure longevity and resistance to corrosive environments. The pumps also feature advanced sealing technologies that minimize leakage risks, thus enhancing operational safety and reliability.

One of the standout technologies in these models is their semi-open impeller design, which provides superior hydraulic performance. This design allows for handling solids and slurries effectively, making them suitable for applications where traditional pumps might struggle. The pumps also boast a user-friendly interface that simplifies operation and maintenance, reducing downtime and operational costs.

The Desa P324E and VP324E models are known for their compact size and high flow rate capabilities, making them suitable for space-constrained installations. In contrast, the P325E series, including the VP325E and its variants, offers enhanced performance specifications with improved energy efficiency. This is achieved through an innovative motor design that ensures lower energy consumption without compromising output.

The pumps are equipped with intelligent monitoring systems, allowing for real-time assessment of performance metrics. This feature enables predictive maintenance, significantly extending the lifespan of the equipment and minimizing unexpected failures. Additionally, the integration of advanced control systems allows users to customize operational parameters according to specific application needs.

Each model within the series can be tailored with various options, including different mounting configurations, motor types, and material finishes. This adaptability ensures that the pumps can be effectively integrated into existing systems and meet specific industry standards.

In summary, the Desa P324E, VP324E, P325E, VP325E, P325E(B), VP325E(B), and VP324E series represent a culmination of engineering excellence, designed to address the demands of modern industrial applications. With their combination of advanced technology, robust design, and flexibility, these pumps offer reliable performance that can be counted on across a range of challenging environments.