Desa PROPANE GAS LOG HEATER installation manual Minimum Non Combustible Material Clearances

Models: PROPANE GAS LOG HEATER

1 36
Download 36 pages 44.94 Kb
Page 10
Image 10

INSTALLING

Continued

10

NOTICE

You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fireplace open- ing is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Minimum Non Combustible Material Clearances

If Not Using Mantel

Note: If using a mantel, go to page 11. If not using a mantel, follow the information on this page.

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8" up. If non combustible material is less than 12", you must install the fireplace hood accessory. See chart below and Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Non combustible material OK.

Between 8" and 12"

Istall fireplace hood acessory (GA6050

 

or GA6052, see Accessories, page 31).

Less than 8"

Non combustible material must be

 

extended to at least 8". See Between 8"

 

and 12", above. If you cannot extend

 

material, you must operate heater with

 

flue damper open.

 

 

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

102318

Page 10
Image 10
Desa PROPANE GAS LOG HEATER installation manual Minimum Non Combustible Material Clearances