SERVICE PROCEDURE

Continued

21.Connect motor wires as follows (see Figure 6, page 10):

white wire—to terminal board. Note: Attach to empty connector on white wire side of terminal board.

red wire—to terminal board. Note: Attach to empty connector on black wire side of terminal board.

blue wire—to thermal switch wire

blue wire—to solenoid valve

green wire—to grounding screw on shell

22.Replace side cover.

23.Replace fan guard.

SPECIFICATIONS

12

Model

RCLP375 and BCLP375

Input Rating (kJ/Hr) (BTU/Hr) 168.800 to 332.325 (160,000 to 315,000)

Fuel

Propane Vapor Only

Fuel Consumption

 

Gallons/Hour

6,8 l/h min./13,6 l/h max.

 

(1.8 Minimum/3.6 Maximum)

Pounds/Hour

3,35kg/h min./ 6,85 kg/h max.

 

(7.4 Minimum/15.1 Maximum)

Supply Pressure To Regulator

 

Minimum (for purposes of

 

input adjustment)

172 kPa (25 psig)

Maximum

1379 kPa (200 psig )

Regulator Outlet Pressure

48 - 138 kPa (7-20 psig)

Motor

1700 RPM

Electric Input

120 V/60 Hz

Amperage

3.0

Weight

 

Heater

18, 1 kg (40 lbs.)

Shipping

21,8 kg (48 lbs.)

Size - L x W x H

 

Heater

89 cm x 33 cm x 51 cm (35 in. x 13 in. x 20 in.)

Carton

94 cm x 40,5 cm x 53,5 cm (37 in. x 16 in. x 21in.)