SERVICE PROCEDURE
Continued
21.Connect motor wires as follows (see Figure 6, page 10):
•white
•red
•blue
•blue
•green
22.Replace side cover.
23.Replace fan guard.
SPECIFICATIONS
12
Model | RCLP375 and BCLP375 |
Input Rating (kJ/Hr) (BTU/Hr) 168.800 to 332.325 (160,000 to 315,000)
Fuel | Propane Vapor Only |
Fuel Consumption |
|
Gallons/Hour | 6,8 l/h min./13,6 l/h max. |
| (1.8 Minimum/3.6 Maximum) |
Pounds/Hour | 3,35kg/h min./ 6,85 kg/h max. |
| (7.4 Minimum/15.1 Maximum) |
Supply Pressure To Regulator |
|
Minimum (for purposes of |
|
input adjustment) | 172 kPa (25 psig) |
Maximum | 1379 kPa (200 psig ) |
Regulator Outlet Pressure | 48 - 138 kPa |
Motor | 1700 RPM |
Electric Input | 120 V/60 Hz |
Amperage | 3.0 |
Weight |
|
Heater | 18, 1 kg (40 lbs.) |
Shipping | 21,8 kg (48 lbs.) |
Size - L x W x H |
|
Heater | 89 cm x 33 cm x 51 cm (35 in. x 13 in. x 20 in.) |
Carton | 94 cm x 40,5 cm x 53,5 cm (37 in. x 16 in. x 21in.) |
100165