9.Line up rear mounting holes in shell with first hole on each side of motor mount (see Figure 8). Note: When holes are lined up, fan should be outside of shell.

10.Holding mounting bolt, carefully reach through fan blades into rear of heater. Be careful not to damage fan pitch. Insert bolt through motor mount and shell. With free hand, attach nut finger tight. Repeat process for other mounting hole.

11.Use 3,1 mm (1/8") hex wrench to loosen setscrew which holds fan to motor shaft (see Figure 9).

12.Slip fan off motor shaft.

13.Clean fan using soft cloth moistened with kerosene or solvent.

14.Dry fan thoroughly.

15.Replace fan on motor shaft. Make sure setscrew is touching back of flat surface on motor shaft (see Figure 10).

16.Place setscrew on flat of shaft. Tighten setscrew firmly (4,52-5,65 [40-50 inch-pounds]).

17.Remove two nuts and bolts securing motor mount to shell.

18.Pull motor and fan from shell. Turn motor and fan around. Carefully place back in shell. Note: Fan will go into shell first.

19.Line up mounting holes in shell with holes on motor mount. Replace four bolts through shell and motor mount. Insert bolts from outside of heater. Tighten nuts firmly.

20.Route motor wires through hole in bottom of shell (see Figure 7, page 10).

Continued

Rear Mounting

Hole

First

Hole

Figure 8 - Fan and Motor Turned Around

Fan

Setscrews

Motor shaft

Figure 9 - Fan, Motor Shaft, and Setscrew Locations

Fan

Hub

 

Motor Shaft

 

Setscrews

 

Figure 10 - Fan Cross Section

11

100165

Page 11
Image 11
Desa BCLP375, RCLP375 owner manual Fan and Motor Turned Around