Desa RFP30TA Securing Hearth Base to Floor, Mounting Heater to Optional Hearth Base

Models: RFP30TA

1 24
Download 24 pages 18.17 Kb
Page 11
Image 11

OWNER’S MANUAL

INSTALLATION

Continued

Securing Hearth Base to Floor

1.

Position hearth base in desired location.

 

Mark holes for drilling (See Figure 16).

 

Remove hearth base.

2.

For carpeted floor, make a small cut with

 

a sharp knife at marked locations before

 

drilling. If securing to a wood floor, drill

 

a 3/4" deep hole using a 1/8" diameter

Bottom of Heater

Shipping

Screw

Base

Mounting Holes

Holes for Securing

C. MOUNTING HEATER WITH OPTIONAL HEARTH BASE (IF APPLICABLE) TO OPTIONAL MANTEL

See Instructions Included With Mantel Kit.

Assembling Mantel

IMPORTANT: Only use the optional man- tels specified in this manual. See Accesso- ries, page 21 for proper mantel kits. This

drill bit. Do not use anchors in wood

floors. If securing to a concrete floor,

Heater to Floor

Sheet Metal Screw

heater is only approved for use with models GMF800/GMU801 series, GM900F/

drill a 1 3/8" deep hole using a 1/4" di-

ameter concrete drill bit. Completely

insert anchors into each hole.

3. Mount heater to hearth base following

steps under Mounting Heater to Op-

tional Hearth Base, below. After

mounting heater, position heater and

hearth base over drilled holes. With

slotted screwdriver, secure hearth base

to floor with four wood screws.

Mounting Heater to Optional Hearth Base

1.Lay heater on its back on a table with the bottom of heater overhanging the edge of the table.

2.Remove 2 shipping screws in bottom of heater. Discard shipping screws.

3.Line up mounting holes on top of hearth base with holes in bottom of heater (see Figure 16).

4.Using a Phillips screwdriver, secure hearth base to heater with four sheet metal screws (see Figure 16).

5.Stand heater up on base.

6.Place hearth insert in hearth base as shown in Figure 17.

7.Assemble brass trim (see steps 1 through 7 under Assembling and At- taching Brass Trim, page 5).

8.Slide base trim on heater base. Attach brass trim to base with two brass screws included as shown in Figure 17.

Figure 16 - Attaching Heater to Hearth Base

Laminate

Sheet

Hearth

Insert

Screw

Brass Base

Trim

Figure 17 - Placing Hearth Insert on Heater Base and Attaching Brass Base Trim

GM901U series, GM700F/GM701U series, GMC22F/GMC23U/GMC24U series, GMC32F/GMC33U series, GMC34F/ GMC35U series and GMC26F/GMC27U/ GMC28F series mantel kits. Using any other mantel will void the CSA approval for this heater. Do not use models GMF800/ GMU801 series, GM900F/GM901U series, GM700F/GM701U series, GMC22F/ GMC23U/GMC24U series, GMC32F/ GMC33U series, GMC34F/GMC35U se- ries and GMC26F/GMC27U/GMC28F mantels with any other product. If the metal base is required with your mantel, the heater must be mounted on the base first

Continued

107100

11

For more information, visit www.desatech.com

Page 11
Image 11
Desa RFP30TA installation manual Securing Hearth Base to Floor, See Instructions Included With Mantel Kit Assembling Mantel

RFP30TA specifications

The Desa RFP30TA is a standout heating solution designed for residential and light commercial spaces. With a powerful output and a variety of features, this gas-fired heater is built to provide efficient warmth while ensuring safety and convenience for users.

One of the main features of the Desa RFP30TA is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of warming spaces of approximately 1,000 square feet, making it suitable for larger rooms or open areas. This makes it an excellent choice for basements, workshops, or other spaces that require effective heating during colder months.

The heater is designed with efficiency in mind. It boasts a high Annual Fuel Utilization Efficiency (AFUE) rating, which translates to lower energy bills and reduced greenhouse gas emissions. Its innovative design ensures that more of the fuel is converted into usable heat, which is not only economical for users but also beneficial for the environment.

As for technology, the Desa RFP30TA incorporates advanced safety features that prioritize user protection. The unit is equipped with a built-in safety shut-off system that automatically turns off the heater if it detects any irregularities in operation. Additionally, it utilizes a reliable thermocouple that monitors flame presence, ensuring that the heater operates safely at all times.

Another characteristic that sets the Desa RFP30TA apart is its versatility in installation. The heater comes with options for both vented and unvented installations, allowing users to choose the best setup for their specific needs. This flexibility means that the unit can be installed in a variety of locations, whether it’s vented to the outdoors or designed for indoor use without the need for a flue.

Furthermore, the Desa RFP30TA is designed with user-friendly controls. The adjustable thermostat allows for precise temperature management, enabling users to maintain their desired comfort level. This feature, combined with the unit's robust build quality, makes it a reliable option for long-term use.

In summary, the Desa RFP30TA is an efficient and powerful heating solution that combines modern technology with user-centric design. With its impressive output, safety features, installation flexibility, and user-friendly controls, it stands as a top choice for those looking for an effective heating solution for their spaces.