Desa RFP30TA installation manual Troubleshooting, Observed Problem Possible Cause Remedy

Models: RFP30TA

1 24
Download 24 pages 18.17 Kb
Page 17
Image 17

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor cable pinched or wet

1.

Free ignitor cable if pinched by any

spark at ODS/pilot

 

 

 

metal or tubing. Keep ignitor cable dry

 

2.

Ignitor electrode not connected to igni-

2.

Reconnect ignitor cable

 

 

tor cable

 

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Ignitor electrode broken

5.

Replace ignitor

 

6.

Bad piezo ignitor

6.

Replace piezo ignitor

 

7.

Ignitor electrode positioned wrong

7.

Replace ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 16) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Safety interlock system has been trig-

3.

Wait one minute for safety interlock sys-

 

 

gered

 

tem to reset. Repeat ignition operation

 

4.

Equipment shutoff valve not fully open

4.

Fully open equipment shutoff valve

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten

 

 

trol valve

 

1/4 turn more

 

6.

Pilot flame not touching thermocouple,

6.

A) Contact local propane/LP gas company

 

 

which allows thermocouple to cool,

 

 

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 16) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace thermocouple

 

8.

Control valve damaged

8.

Replace control valve

 

 

www.desatech.com

 

Continued

107100

17

For more information, visit www.desatech.com

Page 17
Image 17
Desa RFP30TA installation manual Troubleshooting, Observed Problem Possible Cause Remedy

RFP30TA specifications

The Desa RFP30TA is a standout heating solution designed for residential and light commercial spaces. With a powerful output and a variety of features, this gas-fired heater is built to provide efficient warmth while ensuring safety and convenience for users.

One of the main features of the Desa RFP30TA is its impressive heating capacity. With an output of up to 30,000 BTUs, it is capable of warming spaces of approximately 1,000 square feet, making it suitable for larger rooms or open areas. This makes it an excellent choice for basements, workshops, or other spaces that require effective heating during colder months.

The heater is designed with efficiency in mind. It boasts a high Annual Fuel Utilization Efficiency (AFUE) rating, which translates to lower energy bills and reduced greenhouse gas emissions. Its innovative design ensures that more of the fuel is converted into usable heat, which is not only economical for users but also beneficial for the environment.

As for technology, the Desa RFP30TA incorporates advanced safety features that prioritize user protection. The unit is equipped with a built-in safety shut-off system that automatically turns off the heater if it detects any irregularities in operation. Additionally, it utilizes a reliable thermocouple that monitors flame presence, ensuring that the heater operates safely at all times.

Another characteristic that sets the Desa RFP30TA apart is its versatility in installation. The heater comes with options for both vented and unvented installations, allowing users to choose the best setup for their specific needs. This flexibility means that the unit can be installed in a variety of locations, whether it’s vented to the outdoors or designed for indoor use without the need for a flue.

Furthermore, the Desa RFP30TA is designed with user-friendly controls. The adjustable thermostat allows for precise temperature management, enabling users to maintain their desired comfort level. This feature, combined with the unit's robust build quality, makes it a reliable option for long-term use.

In summary, the Desa RFP30TA is an efficient and powerful heating solution that combines modern technology with user-centric design. With its impressive output, safety features, installation flexibility, and user-friendly controls, it stands as a top choice for those looking for an effective heating solution for their spaces.