6
INSTALLATION
Hearth Kit Assembly and Installation
INSTALLATION
Continued
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1.Close equipment shutoff valve (see Figure 5).
2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
3.Check all joints from gas meter to equipment shutoff valve (see Figure 5). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
4.Correct all leaks at once.
Nut
Burner Manifold
Knockout
Plugs
Burner Clamp
Equipment Shutoff Valve
Gas Meter
Burner Pan
(Front)Burner Inlet
Screw Fitting
Figure 6 - Installing Burner
Installation and Gas Connection
1. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward.
2. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant.
3. Install adapter fitting onto the burner inlet fitting using thread
Figure 5 - Checking Gas Jointssealant on male threads of burner inlet fitting (see Figure 7). Adjust to most convenient position.
4. Install the gas connector tube to the gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.
HEARTH KIT ASSEMBLY AND INSTALLATION
Kit Assembly - Dual-Flame Burner
Gas Connector Tube
1. | Determine which side the gas line will be coming into the fire- |
| place. |
2. | Using a hammer and screw driver, remove knockout plug from the |
| side of the pan that corresponds to the gas line (see Figure 6). |
Burner Pan Assem- bly (Facing Front of Fireplace)
Adapter Fitting
3. | Unscrew burner inlet fitting from burner manifold. |
4. | Place burner manifold in pan with threaded opening facing |
| open knockout plug. |
5. | Using thread sealant (resistant to the action of propane/LP gas) |
| on larger end of fitting, screw the burner inlet fitting through |
| hole and into burner manifold (see Figure 6). Tighten using |
| a wrench. |
6. | Using burner clamp, screw, and nut provided, assemble clamp |
| to pan (“U” style and triple burners only). This will hold the |
| burner manifold in place. |
Figure 7 - Connecting Gas to Appliance
OPTIONAL GA9050A ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLY
For additional convenience and safety, or for propane/LP conver- sion, an optional ON/OFF safety valve/pilot kit is available. See Accessories, page 15.
WARNING: You must use a ON/OFF safety valve/ pilot kit for propane/LP conversion.
For more information, visit www.desatech.com