INSTALLATION

Hearth Kit Assembly and Installation

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 5).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 5). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Nut

Burner Manifold Kit Assembly - Dual-Flame Burner

Knockout Manual background

Plugs

Burner Clamp

Equipment Shutoff Valve

Gas Meter

Burner Pan

(Front)Burner Inlet

Screw Fitting

DUAL-FLAME

Figure 6 - Installing Burner

Installation and Gas Connection

1. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward.

2. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant.

3. Install adapter fitting onto the burner inlet fitting using thread

Figure 5 - Checking Gas Jointssealant on male threads of burner inlet fitting (see Figure 7). Adjust to most convenient position.

4. Install the gas connector tube to the gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.

HEARTH KIT ASSEMBLY AND INSTALLATION

Kit Assembly - Dual-Flame Burner

Gas Connector Manual background Tube

1.

Determine which side the gas line will be coming into the fire-

 

place.

2.

Using a hammer and screw driver, remove knockout plug from the

 

side of the pan that corresponds to the gas line (see Figure 6).

Burner Pan Assem- bly (Facing Front of Fireplace)

Adapter Fitting

3.

Unscrew burner inlet fitting from burner manifold.

4.

Place burner manifold in pan with threaded opening facing

 

open knockout plug.

5.

Using thread sealant (resistant to the action of propane/LP gas)

 

on larger end of fitting, screw the burner inlet fitting through

 

hole and into burner manifold (see Figure 6). Tighten using

 

a wrench.

6.

Using burner clamp, screw, and nut provided, assemble clamp

 

to pan (“U” style and triple burners only). This will hold the

 

burner manifold in place.

Figure 7 - Connecting Gas to Appliance

OPTIONAL GA9050A ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLY

For additional convenience and safety, or for propane/LP conver- sion, an optional ON/OFF safety valve/pilot kit is available. See Accessories, page 15.

Manual background WARNING: You must use a ON/OFF safety valve/ pilot kit for propane/LP conversion.