Image 9
OPERATING APPLIANCE

OPERATING APPLIANCE

For Your Safety Read Before Lighting

Lighting Instructions

Gas Shutoff Valve Operation

Curing Logs

Operating Instructions for GA9050A

OPERATING APPLIANCE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WHAT TO DO IF YOU SMELL GAS WARNING: Keep flue open when operating unit.

Flame Adjustment WARNING: If you do not follow these instructions exactly,afireorexplosionmayresultcausingproperty damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information, above.

2.Turn the gas shutoff valve to OFF.

3.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Follow the safety information above. If you don't smell gas, go on to the next step.

4.Light a match and lay it on top of the pan material about 2" from the end of the supply side of the pan

5.Slowly turn the gas shutoff valve ON until the burner ignites. If the burner doesn’t ignite within 10 seconds with the match burning, turn the shutoff valve OFF and repeat steps 1 through 4 again.

GAS SHUTOFF

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the gas shutoff valve coun-

terclockwise Shutting Off Appliance to open or clockwise Manual background to close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise Manual background to the OFF position.

9

CURING

LOGS

During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

Ignite a 2" flame and maintain it for 1 hour.

Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.

OPERATING INSTRUCTIONS

FOR GA9050A

Note: Operation instructions for GA9150A Remote Ready Valve/ Pilot Kit will be included with the kit.

1.STOP! Read the safety information, column one this page.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise Manual background to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas around log set and near floor. If you smell gas, STOP! Refer to the National Fuel Gas Codes, ANSI Z233.1/NFPA54, Section 5.3, Air for Combustion and Ventilation. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise Manual background to the PILOT position and press in. Keep control knob pressed in for five

(5) seconds.

Note: You may be running this log set for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Control Knob

Pilot

 

Ignitor

 

 

ON

OFF

 

FROM "PILOT" POSITION

 

SLIGHT PUSH TO

Off

On

PULL PUSH

 

TURN OFF

 

ON OFF FROM "PILOT" POSITION SLIGHT PUSH TO TURN OFF PULL PUSH

SLIGHT PUSH TO TURN OFF PULL PUSH

ON OFF FROM "PILOT" POSITION

Figure 18 - Ignitor and Control Knob