Desa RH10PT installation manual Checking GAS Connections for Permanent GAS Supply

Models: RH10PT

1 20
Download 20 pages 36.5 Kb
Page 10
Image 10

INSTALLATION

Continued

CHECKING GAS CONNECTIONS FOR PERMANENT GAS SUPPLY

WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detec- tion fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LPsupply and heater. See guidelines under Connecting to Permanent Gas Supply, page 8.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by opening propane/LP supply tank valve or using com- pressed air.

4.Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 14).

2.Pressurize supply piping system by either opening propane/LP supply tank valve or using compressed air.

3.Check all joints from supply tank to equip- ment shutoff valve (see Figure 15). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 14).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 15). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Lighting Instructions, page 11). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appli- ance, page 12).

8.Replace front panel.

Equipment

 

Open

 

Shutoff Valve

 

 

Closed

Figure 14 - Equipment Shutoff Valve

Control Valve Location

Propane/LP

Supply

Tank

Equipment

Shutoff

Valve

Figure 15 - Checking Gas Joints

10

www.desatech.com

110373-01E

Page 10
Image 10
Desa RH10PT Checking GAS Connections for Permanent GAS Supply, Test Pressures In Excess Of 1/2 Psig 3.5 kPa