Desa RJ70, RJ45 Continued, Troubleshooting, Observed Fault, Possible Cause, Remedy, ters, page

Models: RJ70 RJ45

1 18
Download 18 pages 56.49 Kb
Page 7
Image 7
Continued

OWNER’S MANUAL

TROUBLESHOOTING

Continued

RJ70

RJ70 WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts

1.

Photocell assembly not properly in-

1.

Make sure photocell boot is properly

off heater after a short period of time

 

stalled (seeing flame)

 

seated in bracket

 

2.

Wrong pump pressure

2.

See Pump Pressure Adjustment, page 8

 

3.

Dirty air output, air intake and lint filters

3.

See Air Output, Air Intake and Lint Fil-

 

 

 

 

 

ters, page 8

 

4.

Dirty fuel filter

4.

See Fuel Filter, page 9

 

5.

Dirt in nozzle

5.

See Nozzle, page 11

 

6.

Dirty photocell lens

6.

Clean photocell lens

 

7.

Defective flame-out control

7.

Replace flame-out control

 

8.

Defective photocell

8.

Replace photocell

 

 

 

 

 

 

 

Heater will not ignite, but motor runs for a

1.

No fuel in tank

1.

Fill tank with kerosene

short period of time

2.

Wrong pump pressure

2.

See Pump Pressure Adjustment, page 8

 

3.

Carbon deposits on spark plug and/or

3.

See Spark Plug, page 10

 

 

improper gap

 

 

 

 

4.

Dirty fuel filter

4.

See Fuel Filter, page 9

 

5.

Dirt in nozzle

5.

See Nozzle, page 11

 

6.

Water in fuel tank

6.

Drain and flush fuel tank with clean

 

 

 

 

 

kerosene. See Storage, Transporting, or

 

 

 

 

 

Shipping,page 5

 

 

 

 

 

 

 

 

WARNING: High voltage!

 

 

 

 

 

 

 

 

 

7.

Electronic ignitor not grounded

7.

Make sure electronic ignitor mounting

 

 

 

 

 

is tight

 

8.

Defective electronic ignitor

8.

Replace electronic ignitor

 

 

 

 

 

 

 

Motor does not start when heater is plugged

1.

Flame-out control not reset

1.

Press flame-out control reset button

in and switched ON, fan rotates slowly or

2.

Binding pump rotor

2.

If fan is hard to turn, see Pump Rotor,

does not turn

 

 

 

 

page 11

 

3.

Defective motor

3.

Replace motor

 

4.

Defective ON/OFF switch

4.

Replace ON/OFF switch

 

5.

No power to heater

5.

Check circuit breaker in electrical panel

 

6.

Bad electrical connections

6.

Check all electrical connections. See

 

 

 

 

 

Wiring Diagrams, page 12

104950

7

Page 7
Image 7
Desa RJ70, RJ45 Continued, Troubleshooting, Observed Fault, Possible Cause, Remedy, See Pump Pressure Adjustment, page