Desa CSG3924NR, RL24NR, VRL24PR Continued, Remote-ReadyModels Only, Installation Items Needed

Models: RL24NR CSG3924PT CSG3924PR VRL30PR CTB3924NT

1 38
Download 38 pages 2.89 Kb
Page 11
Image 11
(Remote-Ready Models Only)

INSTALLATION

Installing Damper Clamp Accessory For Vented Operation Installing Heater Base Assembly

11

INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

(Remote-Ready Models Only)

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a manually-controlled, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles re- quirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 34). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

INSTALLING HEATER BASE ASSEMBLY

Area of Various Standard WARNING: You must secure this heater to fire- place floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

Installation Items Needed WARNING: If installing in a sunken fireplace, spe- cial care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and con- trols being damaged. Raise fireplace floor with noncom- bustible material. Make sure material is secure.

Manual background CAUTION: Do not pick up heater base assembly by burners. This could damage heater. Only handle base assembly by sides of base.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning of Thermostat Sensing Bulb, page 27.

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

Chimney

Minimum Permanent

Height (ft.) Flue Opening (sq. ins.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Damper

 

Clamp

 

 

Damper Clamp

Damper

Damper

Damper

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose and fitting (not provided) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

electric drill with 3/16" drill bit (metal or masonry as applicable)

flathead screwdriver

1.Connect fitting to base as shown in Figure 11. Connect approved flexible gas hose to fitting in base (see Figure 11). IMPORTANT: Hold gas fitting with wrench when connecting flexible gas hose.

Flexible Gas Hose (if

 

allowed by local codes)

Fitting

Masonry Fireplace

Manufactured Fireplace

Figure 11 - Attaching Flexible Gas Hose to Heater

Figure 10 - Attaching Damper Clamp

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

110021-01C

Page 11
Image 11
Desa CSG3924NR, RL24NR, CTB3924NT Installation, Continued, Remote-ReadyModels Only, Area of Various Standard Round Flues