VENT-FREE NATURAL GAS PEDESTAL STOVE
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
* An CSA |
shutoff valve with 1/8" NPT tap is an ac- |
ceptable alternative to test gauge connec- |
tion. Purchase the optional CSA design- |
certified equipment shutoff valve from your |
WARNING: Never connect heater to private
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 6).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.
dealer. See Accessories, page 22. |
Back View
| CSA | |
From Gas Meter | Shutoff Valve With 1/8" NPT Tap* | |
| ||
(5" W.C.** to 10.5" | Approved Flexible Gas Hose | |
W.C. Pressure) | ||
(if allowed by local codes) | ||
|
Side View
Front of
Stove
Unit
Gas Regulator Inlet Connection
Sediment Tee Joint |
|
| |
Trap | Pipe |
| Gas |
Nipple |
| ||
| 3" Minimum | Regulator | |
| Cap | ||
|
| of Heater |
Figure 6 - Gas Connection
*Purchase the optional CSA
**Minimum inlet pressure for purpose of input adjustment.
Figure 5 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
For more information, visit www.desatech.com | 8 | 105683 |