THEORY OF

HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR

THEORY OF

OPERATION

The Fuel System: The motor turns the fuel pump. The fuel pump pulls fuel from the fuel tank. The fuel pump pushes fuel through a filter and a solenoid valve and out the burner head nozzle. A fine mist of fuel is sprayed into the combustion chamber.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The electronic ig- nitor sends voltage to the spark plug. The spark plug ignites the fuel and air mixture.

The Flame-Out Control System: This system causes the heater to shut down if the flame goes out. It also allows the fan to continue running after normal shutdown of heater. This cools the combustion chamber.

FUELS

FUELSWARNING: Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gaso- line, naphtha, paint thinners, al- cohol, or other highly flammable fuels.

Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. Using heavy fuels will result in:

clogged fuel filter and nozzle

carbon build-up on spark plug

the need of non-toxic anti-icer in fuel during very cold weather

IMPORTANT: Use a KEROSENE ONLY storage container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause flame-out control to shut down heater. Foreign matter may also re- quire you to clean fuel system often.

VENTILATION

VENTILATION WARNING: Follow the mini- mum fresh, outside air ventila- tion requirements. If proper fresh, outside air ventilation is not pro- vided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ventilation be- fore running heater.

Fresh Air Opening

Requirements

 

Square Feet

Heater Size

Opening

350,000 Btu/Hr

10.5

600,000 Btu/Hr

18.0

Note: If you use more than one heater, provide extra fresh air. Provide a fresh air opening of at least three square feet for each 100,000 Btu/Hr rating.

 

 

 

Solenoid

Fuel Pump/

Combustion

 

Burner

Valve

Fuel Filter

Chamber

Spark

Fan

Motor

 

Plug

Head

 

 

 

 

 

 

 

 

Clean

 

 

 

 

Heated

 

 

 

 

Air Out

 

 

 

Cool

 

 

 

 

Air In

Fuel

Pickup

Line

Fuel Tank

Nozzle

Fuel Line To

Electronic Ignitor

Fuel

Solenoid Valve

Filter

 

 

 

Air for Combustion

Fuel

and Heating

 

Figure 3 - Cross Section Operational View

 