HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR
PREVENTATIVE MAINTENANCE SCHEDULE
Item
WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur.
How Often | How To |
Fuel tank | Flush every | See Storing, Transporting, or Shipping, page 5 |
| as needed |
|
Filler neck screen | Check for particles in fuel when filling fuel | Lift out of fuel tank and rinse with clean |
| tank. Clean when dirty | kerosene |
Fuel filter assembly (Fuel tank) | Clean twice a heating season or replace as | See Fuel Filters, page 12 |
| needed |
|
Fuel filter lines | Check and tighten loose connections occa- | See Fuel Lines, Page 12 |
| sionally |
|
Fuel filter (Pump) | Clean fuel filter element every 250 hours | See Fuel Filters, page 12 |
Spark plug | Clean and regap every 300 hours of opera- | See Spark Plug, page 10 |
| tion or replace as needed |
|
Fan blades and air deflectors | Clean each season or as needed | See Fan Blades and Air Deflectors, page 10 |
Air passages around burner head | Check each season for dirt and debris | Remove debris and trash with a clean, soft |
|
| cloth |
Motor | Not required, permanently lubricated |
|
6 | 106029 |