Maintenance (con’t)
Cleaning the Condenser (Monthly)
This cleaning should be done monthly or more often if necessary.
In order to guarantee an efficient refrigerating system, it is essential that the condenser be properly cleaned at regular intervals, according to the following procedures:
• Unplug the machine. | (Figure HH) |
•Remove the back panel and filter. Using a dry brush or vacuum, remove the dust that has accumulated between the fins of the condenser (see fig HH).
Replacing the Lightbulbs (As Needed)
• Unplug the machine.
Lid Lights
• Unplug the cord to the lid and remove the lid from the machine.
(Figure II)
•In order to access the lightbulb in the merchandising cover, insert a quarter in the slot on the small panel on the top of the cover (DA) and rotate the quarter to pop the panel open (see fig. II).
•Holding the merchandising cover with the top open, carefully remove the lightbulb (see fig. JJ).
•Insert the new bulb and replace the light cover.
(Figure JJ)
• Place lid on machine and plug lid cord back into lid.
Rear Merchandiser Lights
•In order to access the lightbulb from the rear
NOTE: Some units may have dual rear backlit merchandiser panels, these function in the same manner as the single panel rear merchandisers.
•Then remove the lightbulb(s) (BA) (see fig. LL).
•Insert the new bulb(s) (BA).
(Figure KK)
•Reassemble the rear
•Plug machine into dedicated outlet.
(Figure LL)
Page 12 | G & MG Series Granita Machine |
|
|