TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period be- fore it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.
❒Turn the RANGE control to the mid position, Dual Brite™ to OFF and the
MAX |
|
|
|
| |
B | O | ON - TIME | DUAL BRITE | ||
| |||||
| O |
|
| ||
| S |
|
|
| |
MIN | T |
|
|
| |
TEST 1 5 2 0 | OFF 3 6 | DUSK TO | |||
RANGE | |||||
| MINUTES | HOUR | DAWN |
Bottom of Sensor
Avoid aiming the sensor at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
| 240° |
8 ft. |
|
(2.4 m) |
|
70 ft. | 100 ft. |
(21 m) | (30.5 m) |
| Boosted |
Maximum Range | Maximum | |
Coverage Angle | ||
|
The detector is less sensitive to motion directly towards it.
MotionMotion
Least Sensitive | Sensor | Most Sensitive |
|
❒ Loosen the clamp screw in the | Clamp | |
sensor ball joint and gently | Screw | |
rotate the sensor. |
| |
❒ Walk through the coverage | Ball | |
area noting where you are | ||
Joint | ||
when the lights turn on. Move | ||
| ||
the sensor head up, down, or |
| |
sideways to change the cover- |
| |
age area.Keep the sensor at |
| |
least 1" (2.5 cm) away from | Aim Sensor | |
the lamps. | ||
Down for Short | ||
❒ Adjust the RANGE as needed. | ||
Coverage | ||
RANGE set too high may | ||
| ||
increase false triggering. |
|
❒ Secure the sensor head's aim by tightening the clamp screw. Do not overtighten the
screw.
❒ Set the amount of TIME you want the lights to stay on after
motion is detected (1, 5, or 20 minutes).
❒Set the DUAL BRITE™ switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs.,
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load. . . . . . Up to 300Watt Maximum Incan- descent [Up to 150 Maximum each lamp holder].
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1 , 5, 20 minutes Replacement lamp. . . T3, 150W halogen maximum
120 VAC
Dual Brite™ Timer . . . Off, 3, 6 hours,
DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
3 |