Desa SBJ18VPA, SMA18VPA, SBJ24VNA, SMA24VNA installation manual Continued, Lighting Instructions

Models: SMA24VNA SBJ18VPA SBJ24VNA SMA18VPA SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, SMA18VPA

1 32
Download 32 pages 335 b
Page 17
Image 17
LIGHTING

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

Manual background WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also iffireplaceopeninghasventsat the bottom, you must open the vents before operating heater.

You must operate this heater withafireplacescreeninplace. Make sure fireplace screen is closed before running heater.

NOTICE:Duringinitialoperationof new heater, burning logs will give offapaper-burningsmell.Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

Manual background WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, start- ing in column 1, of this page.

2.Make sure equipment shutoff valve is fully open.

3.Set switch in the OFF position.

4.Press in and turn control knob clockwise Manual background to the OFF position (see Figure 18).

Manual background WARNING: Burner will come on automatically within one min- ute when the switch is in the ON position after the pilot is lit.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, starting in column 1 of this page. If you donʼt smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise Manual backgroundto the PILOT position. Press in control knob for five (5) seconds (see Figure 18).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot. If needed, keep pressing ignitorbutton until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 18.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8, page 16.

9.Slightly push in and turn control knob coun-

terclockwise Manual background to the ON position.

10.Wait one minute and move switch to the ON position to light burner. Note: AUTO is only functional when using optional remote control accessories.

11.Set flame adjustment knob to any level between HI and LO.

Control Knob

 

Switch

 

 

 

 

 

 

 

 

 

 

 

Piezo Ignitor

Flame Adjustment Knob

Figure 18 - Control Knob and Ignitor Button Location, Manual Controlled

114744-01B

www.desatech.com

17

Page 17
Image 17
Desa SBJ18VPA, SMA18VPA, SBJ24VNA, SMA24VNA installation manual Continued, Lighting Instructions